Zirconia O2 Sensors Oxygen Analyzer - OXY-Flex

  • Zirconia O2 Sensors Oxygen Analyzer
  • Zirconia O2 Sensors Oxygen Analyzer
  • Zirconia O2 Sensors Oxygen Analyzer
Mouse over image to zoom

• Supply voltage: 24V DC ± 10%
• Supply current: 500mA max. at 24V DC
• Digital output: RS232
• High accuracy linear output
• Externally triggered automatic or manual calibration
• Can be calibrated in fresh air (20.7% O2 ) or to any other known O2 concentration
• Selectable output filtering allows adaptive, fast and dynamic or slow and stable output

  • Model Number: OXY-Flex
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

OXY-Flex Oxygen Analyser Description
The OXY-Flex Oxygen Analyser is suitable for measuring in oxygen closed systems, such as ventilation pipes and boiler exhaust flues. 

The OXY-Flex Oxygen Analyser is designed to measure the oxygen concentration in air or gas mixtures with temperatures of -100 to 400⁰C. The oxygen analyser employs a well proven, small zirconium dioxide based element at its heart and due to its innovative design does not require a reference gas. The oxygen sensor element is mounted in the tip of the stainless steel probe and is protected by a sintered stainless steel cap. The IP65 waterproof die-cast aluminium housing accommodates the electronics and provides the interface for the customer to connect to.

The OXY-Flex Oxygen Analyser uses a unique closed loop measurement system. While the sensor continuously measures the oxygen level, a heartbeat signal is also generated providing an immediate warning of any failures.

The OXY-Flex can be configured to output measuring ranges of 0-25% O₂ or 0-100% O₂. The entire measurement range is linear in both cases. The outputs can be configured to either 4-20mA and 0-10Vdc outputs or an RS232 serial communications interface.


OXY-Flex Zirconia O2 Sensors Oxygen Analyzer FEATURES
• High accuracy linear output
• Externally triggered automatic or manual calibration
• Can be calibrated in fresh air (20.7% O2 ) or to any other known O2 concentration
• Selectable output filtering allows adaptive, fast and dynamic or slow and stable output


OXY-Flex Zirconia O2 Sensors Oxygen Analyzer BENEFITS
• Cycling 3.3V DC logic output allows direct monitoring of the O2 sensor pump cycle for diagnostic purposes
• No reference gas required


OXY-Flex Zirconia O2 Sensors Oxygen Analyzer TECHNICAL SPECIFICATIONS

Supply voltage
24V DC  ± 10%
Supply current
500mA max. at 24V DC
Digital output
RS232
Analogue output
4 ~ 20mA; load 600Ω max.
or 0 ~ 10V DC ; load 10kΩ min.
Housing temperature limits
    Storage:
    Operating:
-10°C to +85°C
-10°C to +85°C
Permissible gas temperatures (probe tip)
    Standard:
    High:
-100°C to +250°C
-100°C to +400°C
Gas flow rate
0 to 10 m/s
Permissible acceleration 
    Repetitive
    Incidental
5g
30g


OXY-Flex Zirconia O2 Sensors Oxygen Analyzer OUTPUT VALUES

Oxygen range (analogue output)
0.1 ~ 25% O2
or 0.1 ~ 100% O2
Oxygen range (RS232 output)
0.1 and 100% O2
Accuracy after calibration
1% O2
Repeatability after calibration
0.5% O2
Output resolution
    Analogue
    Analogue
    Digital RS232
4 ~ 20mA  0.01mA
0 ~ 10V DC 0.01V         
0.01% O2
Response time
< 15s
Warm up time (prior to sensor operation)
60s
Output stabilisation time

~ 180s


OXY-Flex Zirconia O2 Sensors Oxygen Analyzer ORDER INFORMATION
Generate your specific part number using the convention shown below. Use only those letters and numbers that correspond to the options you require - omit those you do not. Include the “OXY-FLEX” prefix.


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service