Oxygen Sensor Interface Board - OXY-LC
• Oxygen range (analogue output): 0.1 ~ 25% O2 or 0.1 ~ 100% O2
• Oxygen range (Modbus RTU): 0.1 ~ 100% O2
• Accuracy after calibration: 0.5% O2
• Repeatability after calibration: 0.5% O2
• Output resolution: 0.01% O2
- Quantity:
- - +
Product Specification
OXY-LC Oxygen Sensor Interface Board Description
The OXY-LC Oxygen Sensor Interface Electronics provides the necessary electronics to power and control SST’s range of zirconium dioxide (ZrO₂) sensors.
The OXY-LC Oxygen Sensor offers various user configurable output variants RS485, PWM, 0-10Vdc and 4-20mA. The RS485 Modbus RTU Protocol offers various benefits over other output types but most importantly it allows complete control of the sensor operation and access to all available information including sensor diagnostics, barometric pressure and pressure sensor temperature.
The adaptive software filtering which enables it to provide a fast response coupled with a stable oxygen output. In addition to this, the OXY-LC Oxygen sensor interface electronics offers a high accuracy linear output for all of our zirconium dioxide oxygen sensors.
The built in pressure sensor allows for barometric pressure compensation and the interface mounted screw terminals offers easy wiring with reverse voltage and transient overvoltage.
OXY-LC Oxygen Sensor Interface Board FEATURES
• Provides the electronics necessary to power and control SST’s range of zirconium dioxide (ZrO 2 ) sensors
• Built in pressure sensor for barometric pressure compensation
• Interface mounted screw terminals for easy wiring with reverse voltage and transient overvoltage
OXY-LC Oxygen Sensor Interface Board BENEFITS
• Adaptive software filtering provides a fast sensor response coupled with a stable oxygen output
• High accuracy linear output
OXY-LC Oxygen Sensor Interface Board TECHNICAL SPECIFICATIONS
Supply voltage
RS485 variant:
Analogue variants:
8 ~ 28V DC
20 ~ 28V DC20 ~ 28V DC
Supply current
600mA max. at 24V DC
1.2A max. at 12V DC
Digital output
RS485 (Modbus RTU)
or PWM
Analogue output
4 ~ 20mA; load 600Ω max
or 0 ~ 10V DC ; load 10kΩ min
Temperature limits
Storage:
Operating:
-40°C to +85°C
-30°C to +70°C
Operating pressure limits
260 ~ 1260mbar absolute
OXY-LC Oxygen Sensor Interface Board OUTPUT VALUES
Oxygen range (analogue output)
0.1 ~ 25% O2
or 0.1 ~ 100% O2
Oxygen range (Modbus RTU)
0.1 ~ 100% O2
Accuracy after calibration
0.5% O2
Repeatability after calibration
0.5% O2
Output resolution
0.01% O2
Response time (step 10-90%)
Fast response sensor connected:
Standard response sensor connected:
4s
15s
Initial warm up time (till stable output)
5 ~ 10mins
Output inactive start up delay (heater warm up)
From OFF to ON mode:
From Standby to ON mode (RS485 only):
60s
20s
OXY-LC Oxygen Sensor Interface Board ORDER INFORMATION
Generate your specific part number using the convention shown below. Use only those letters and numbers that correspond to the options you require — omit those you do not
Digital Variant
O X Y - L C - 4 8 5
Analogue Variants
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Short Probe Zirconia Oxygen Sensors (Zirconia O2 Sensor)
-
Oxygen Analyser
-
Zirconia Oxygen Analyser
-
Zirconia Oxygen Sensor System
-
Screwfit Zirconia Oxygen Sensor
-
Screwfit Zirconia Oxygen Sensor
-
Flange Mount Zirconia Oxygen Sensor
-
Miniature Zirconia Oxygen Sensors
-
Zirconia Oxygen Sensor System
-
Zirconia Oxygen Sensor System