Zirconia Oxygen Sensor System - O2S-FR-T2-18BM-C-RS485
• Oxygen range (Modbus RTU): 0.1-100% O2
• Long life, non-depleting technology
• Integral heating element
• High accuracy
• Linear output signal
• No reference gas required
• No need for temperature stabilisation
• Probe mounting positions available; 28mm
• M18x1.5 screw mounting
- Quantity:
- - +
Product Specification
O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System Description
The Zirconia Oxygen Sensor System offers a complete solution, removing the need for customers to develop their own electronics. Frequently used in combustion control systems, burning coal, oil, gas and biomass and in oxygen generation systems.
The Zirconia Oxygen Sensor System consists of SST’s fast response (<4s T90) zirconium dioxide (ZrO₂) screw fit sensor in conjunction with the OXY-LC oxygen sensor interface board.
O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System FEATURES
• Fast response zirconium dioxide (ZrO2) sensor in conjunction with the OXY-LC oxygen sensor interface board
• Long life, non-depleting technology
• Integral heating element
• High accuracy
• Linear output signal
O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System BENEFITS
• No reference gas required
• No need for temperature stabilisation
• Probe mounting positions available; 28mm
• M18x1.5 screw mounting
O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System TECHNICAL SPECIFICATIONS
Supply voltage RS485 output variant: |
8-28V DC |
Supply current |
600mA max. at 24V DC 1.2A max. at 12V DC |
Digital output |
RS485 (Modbus RTU) |
Pump impedance at 700°C |
< 6kΩ |
Permissible gas temperature |
-100°C to +250°C |
Gas flow rate |
0-10m/s |
Operating pressure limits |
260-1260mbar absolute |
Mounting thread |
M18 x 1.5 |
O2S-FR-T2-18BM-C-RS485 Zirconia O2 Sensor System OUTPUT VALUES
Oxygen range (Modbus RTU) |
0.1-100% O2 |
Accuracy after calibration |
0.5% O2 |
Output resolution |
0.01% O2 |
Response time (10-90% step) |
< 4s |
Initial warm up time (till stable output) |
5 - 10mins |
Output inactive start up delay (heater warm up) From Standby to ON mode (RS485 only): |
20s |
O2S-FR-T2-18BM-C-RS485 Zirconia O2 Sensor System ORDER INFORMATION
Referring to the tables below will allow you to tailor a system to suit your specific requirements.
Interface Board
PCB
Part Number |
O2
Measure
Range |
Output
Type |
Heater
Voltage |
OXY-LC-485 |
0.1% and 100% |
Modbus RTU |
Configurable |
Sensor
Sensor Part Number
Probe Length
O2S-FR-T2-18BM-C
28mm
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Short Probe Zirconia Oxygen Sensors (Zirconia O2 Sensor)
-
Oxygen Analyser
-
Zirconia Oxygen Analyser
-
Zirconia Oxygen Sensor System
-
Screwfit Zirconia Oxygen Sensor
-
Screwfit Zirconia Oxygen Sensor
-
Flange Mount Zirconia Oxygen Sensor
-
Miniature Zirconia Oxygen Sensors
-
Oxygen Sensor Interface Board
-
Zirconia Oxygen Sensor System