• Flow: 20 ~ 200 mn/sec | 65 ~ 650 sfps
• Bi-directional: Standard
• Pressure: 0 ~ 16 bar | 0 ~ 250 psi gauge
• Temperature: -40 ~ 150 °C | -40 ~ 320 °F. Icing should be avoided
• Gas types: Wet compressed air, dry compressed air, nitrogen and inert gases
• Output: RS485 (Modbus RTU) digital | 4 … 20 mA analog
• Probe length: 400 mm | 15" (other lengths on request)
• Power supply: 12 ~ 24 VDC
• Approvals: CE, UL/CUL

  • Model Number: VPFlowScope DP
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

VPFlowScope DP Compressed Air Flow Meters Description
The VPFlowScope DP measures mass flow, temperature and pressure simultaneously and is optimized for wet compressed air measurements. The patented design has a bright blue LCD display which provides real-time information that, in combination with the built-in data logger, enables you to make recordings for certain periods of time. In turn, you can use our VPStudio software to process this data and print reports for real-time measurements.

VPFlowScope DP Compressed Air Flow Meters Features and benefits 
• For wet compressed air
• Three sensors in one instrument
• Standard Modbus and 4 … 20 mA
• Bi-directional

VPFlowScope DP Compressed Air Flow Meters Applications
• Air audits
• Compressor efficiency monitoring
• Air treatment equipment (drier/filter) monitoring

VPFlowScope DP Compressed Air Flow Meters Specifications

Flow measurement
(minimum detection level and max flow rate shown)
Flow range
20...200 mn/sec
65…650 sfps
Accuracy
2% of reading under calibration conditions
Recommended pipe diameter: 50mm | 2 inch and up
Reference conditions
0°C, 1013.25 mbar - DIN1343
32°F, 14.65 psi
Gas temperature
-40....150°C
-40..302°F Icing should be avoided
Gases
Compressed air, non aggressive gasses and non combustible
gasses, 95% non condensing gases



Pressure sensor
Range
0...16 bar gauge
0…250 psi gauge
Accuracy
+/- 1.5% FSS (0...60°C)
+/- 1.5% FSS (32..140°F)



Temperature sensor
Range
-40....150°C
-40…302°F
Accuracy
+/- 1°C




Display
Technology
Liquid crystal
Back light 
Blue with auto power save
Memory
2.000.000 point memory



Mechanical
Probe length
400 mm
15.7 inch
Probe diameter
12.7 mm
0.5 inch
Process connection
Compression fittings, 0.5 inch, NPT thread
IP grade
IP52 when mated to display module
IP63 when mated to connector cap
Wetted materials
Alu, SS316, epoxy

Ambient temperature
0..60°C
32 .. 140°F
Ambient humidity
10 - 95%. Avoid condensation at all times




Inputs and outputs
Analog
4..20mA or pulse, selectable via installation software
Serial IO
Modbus RTU
Supply
12..24 VDC +-10% CLASS 2 (UL)
Power consumption
150mA at 24VDC

VPFlowScope DP Compressed Air Flow Meters Order information
The VPFlowScope DP is available in 1 length (400 mm) only. You can choose some options:
Order Code
Flow range
Option
Length
Option
Display
VPS.R200.P4DP
20 to 200 mn/sec
P400
400 mm length
D0
No display, No connector cap




D10
Display




D11
Display + 2M point logger




D2
Connector cap