UV Radiometer 5.0 - GUVx-T1xGS5-3LW5

  • UV Radiometer 5.0
  • UV Radiometer 5.0
Mouse over image to zoom

- Electro-Optical Characteristics
- Power : Display: AC 85 ~ 265V (50/60Hz)
- Fixing method: Panel Insertion
- Detection Power Range: 19,999 ㎼/㎠ Max
- Working humidy: 35~85%RH
- Detection Range:
GUVV-T11GS5-3LW5: 230~395nm
GUVB-T12GS5-3LW5: 220~320nm
GUVC-T11GS5-3LW5​: 220~280nm

  • Model Number: GUVx-T1xGS5-3LW5
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

GUVx-T1xGS5-3LW5 UV Radiometer 5.0 Description
 Display : Absolute Power (AP), Relative Power (RP), and Accumulative Time (AT)
 Output : DC Voltage, Current, and Relay

GUVx-T1xGS5-3LW5 UV Radiometer 5.0 Applications
 - UV Purification (Water)
 - Water treatment

GUVx-T1xGS5-3LW5 UV Radiometer 5.0 Constitution
 Display, Sensor Probe

Sensor Probe Dimensions

Thread/Length for Mounting
Diameter (mm)
Window (mm)
Wrench Size (mm)
Depth (mm)
Length (mm)
 Case Material
PT1/4 "/12 mm
21 7 19 63 67 STS 316-L

GUVx-T1xGS5-3LW5 UV Radiometer 5.0 Absolute Maximum Ratings
Parameter
Value
Unit
Remark
Operating Temperature
-30 ~ 85
°C Sensor Probe
0 ~ 50
°C
Display
Working humidy
35 ~ 85
%RH
Display
Power Supply
85 ~ 265
VAC
50/60 ㎐


GUVx-T1xGS5-3LW5 UV Radiometer 5.0 Electro-Optical Characteristics (at 25°C)

Parameter
Min.
 Peak
 Max.
Unit
Remark
Detection Power Range
0

19,999 μW/cm2
Detection Range
GUVV-T11GS5-3LW5
230 350 395 nm 10% of Max
GUVB-T12GS5-3LW5
220 300 320 nm
GUVC-T11GS5-3LW5
220 254 280 nm

GUVx-T1xGS5-3LW5 UV Radiometer 5.0 Function
 1. Display : Absolute Power (μW/cm2) , Relative Power (%), and Accumulative Time (Hours).
 2. Output : DC Voltage (1~5V DC), DC Current (4-20mA, 300 Ω max load), Relay (NC/NO, 250VAC 3A/30VDC 3A)

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service