ToughSonic CHEM 35 Ultrasonic Level Sensor - LVL-500 Series

  • ToughSonic CHEM 35 Ultrasonic Level Sensor
  • ToughSonic CHEM 35 Ultrasonic Level Sensor
Mouse over image to zoom

• Optimum Range: 25 ft. (7.6 m)
• Max Range: 35 feet (10.7 m)
• Deadband: Typ. < 12 in. (30.5 cm)
• Temperature: -40 to 158 ℉ (-40 to 70℃)
• Outputs: Five selectable, plus serial data
• Humidity: 0 to 100% operating
• Transducer: Rugged piezoelectric
• Compensation: Temperature compensated
• Protection: NEMA-4X, NEMA-6P, IP68

  • Model Number: LVL-500 Series
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

ToughSonic CHEM 35 Level Sensor
Liquids or Solids in Chemically Aggressive Environments

The ToughSonic CHEM 35 is designed for distance measurement applications where corrosive chemical liquids or gasses are present, but it is an excellent sensor for benign environments as well. The maximum range of 35 feet (10.7 meters) is the longest range model in the ToughSonic CHEM sensor family.

The ToughSonic CHEM 35 is sealed in a PVDF (Kynar) housing. It is fully submersible, chemical resistant and shock resistant. It has a potted-in 9-wire cable that connects up to five simultaneous analog and/or switch outputs plus a serial interface. It is fully configurable with SenixVIEW configuration and analysis software.

Please see the full line of ToughSonic and ToughSonic CHEM sensors for alternative ranges, sizes and housing materials.

Non-Contact Ultrasonic Distance & Level Measurement

LVL-500 Series Chemically Resistant Ultrasonic Level Sensor Features
Level Measurements
• Long or short measurements
• Unaffected by optical factors like color and transparency
• Computer (PC) software allows remote adjustment
Packaging & Performance
• Durable housing for long life
• Bottom and top thread mounts
• Short & overload protected I/O
• Adjustable filters compensate for tank mixers or turbulence
• Temperature compensation for improved accuracy
• Adjustable sensitivity
Free Functionality
Use adjustable interface features like switch hysteresis and time delays to build complete solutions such as pump controls to maintain level. Save cost by eliminating PLCs, delay circuits and time delay relays!

LVL-500 Series Chemically Resistant Ultrasonic Level Sensor Specifications

Optimum Range

 25 ft. (7.6 m)

Max Range

 35 feet (10.7 m)

Deadband

 Typ. < 12 in. (30.5 cm)

Adjustment

 SenixVIEW software

Case Material

 PVDF

Configuration

 Stored in non-volatile memory

Temperature

 -40 to 158 ℉ (-40 to 70 ℃)

Outputs

 Five selectable, plus serial data

Humidity

 0 to 100% operating

Transducer

 Rugged piezoelectric

Compensation

 Temperature compensated

Protection

 NEMA-4X, NEMA-6P, IP68

Resolution

 Digital 0.0135 in. (0.344 mm); Analog 4099 steps (0-10 VDC), 3279 steps (4-20 mA)

Repeatability

 Nominal 0.2% of range @ constant temp. Affected by target, distance, environment

Update Rate

 5 Hz (200 ms), SenixVIEW adjustable; affected by SenixVIEW filter selections

Voltage Output

 0-10, 0-5 VDC or PC customized; 10 mA max. (*)

Current Loop #1

 Current sourcing 4-20 mA or PC customized, max. loop 450Ω(*)

Current Loop #2

 Current sinking 4-20 mA or PC customized, max. loop 450Ω(*)

Sinking Switch

 150 mA max. @ 40 VDC max., teachable set point & polarity, fault indication

Sourcing Switch

 150 mA max. @ input voltage, teachable set point & polarity, fault indication

RS-232, RS-485

 Modbus protocol, 9600-115200 baud (selectable), 8 data bits, 1 stop, no parity

Target Requirements

Target

 Detects flat or irregular surfaces. Target surface must reflect sound back to sensor.

Max. Distance

 Affected by size, shape, orientation of target (sound level reflected back to sensor), environment

 Restrict use to Optimum Range when using over a wide range of environmental conditions

Granular

 Solids De-rate max range by 50%; range affected by material density and orientation

Orientation

 Orient sensor beam perpendicular to target surface for best performance

Optical

 Unaffected by target color, light level, transparency or other optical characteristics


LVL-500 Series Chemically Resistant Ultrasonic Level Sensor Connections

Cable Connection

 Wire

 Description

Power

 Brown

 10-30 VDC @ 50 mA maximum; Typical: 45 mA @ 24 VDC (**)

Ground

 Blue

 Power and interface common

Voltage Output *

 Violet

 0-10 VDC, 0-5 VDC or custom end values between 0 and 10 VDC

Current Loop Output *

 Green

 4-20 mA sourcing (adjustable end values between 4 and 20 mA)

Current Loop Output *

 Orange

 4-20 mA sinking (adjustable end values between 4 and 20 mA)

Switch #1 Output

 Black

 Sinking ("NPN") or Sourcing ("PNP"), user selected

Switch #2 Output

 White

 Sinking ("NPN") or Sourcing ("PNP"), user selected

RS-232 out / RS-485-

 Gray

 Serial data connection (depends on model - see model selection)

RS-232 in / RS-485+

 Yellow

 Serial data connection (depends on model - see model selection)

(*) Analog outputs share common distance endpoints. Both 4-20 mA outputs share the same adjustable max / min values. The max. loop resistance is derated below 15 VDC input voltage.
(**) At default update rate. Output currents not included. Sensitivity reduced below 15 VDC input voltage

LVL-500 Series Chemically Resistant Ultrasonic Level Sensor Part Numbers

Model Number

 Description

LVL-500-232

 Serial RS-232 interface (PC COM port compatible)

LVL-500-485

 Serial RS-485 interface (allows addressable multi-sensor networks)

also offers interconnection, communication, mounting, and display components


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service