• Target gas: Hydrogen
• Heater voltage: 5.0 V ± 4%
• Circuit voltage: 5.0 V ± 4%
• Operating temperature: -10°C to 60°C
• Storage temperature: -20°C to 70°C
• Relative humidity: Less than 95% RH
• Sensor resistance: 0.5 kΩ to 5 kΩ
• Industrial gas leak detector

  • Model Number: SP-19-01
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

SP-19-01 Hydrogen Sensor H2 Sensor Description
The SP-19-01 is a tin dioxide semiconductor gas sensor which has a high sensitivity and selectivity to hydrogen.

Using this model, detection of hydrogen is possible from low concentration ranges.

SP-19-01 Hydrogen Sensor H2 Sensor Application
• Industrial gas leak detector

SP-19-01 Hydrogen Sensor H2 Sensor Specifications

Standard Operating conditions
Symbol
Parameter
Specification
Conditions etc.
VH
Heater voltage
5.0 V ± 4 %
AC or DC
VC Circuit voltage
5.0 V ± 4 %
AC or DC
RL Load resistance
Variable
PS < 15 mW
RH Heater resistance
56 Ω ± 2 Ω
at room temperature
PH Heater power consumption
315 mW (Typical value)
PH = VH2 / RH
PS
Power dissipation of
sensing element
Less than 15 mW
PS =(VC - VRL)2/RS
Environmental conditions
Symbol
Parameter
Specification
Conditions etc.
Tao
Operating temperature
-10°C to 60°C
Recommended range
Tas
Storage temperature
-20°C to 70°C
RH
Relative humidity
Less than 95% RH
(O2)
Oxygen concentration
21% ± 1%
(Standard condition)

Absolute minimum level:
more than 18%
The sensitivity characteristics are influenced by the
variation in oxygen concentration. 

Sensitivity characteristics
Model
SP-19-01
Symbol
Parameter
Specification
Conditions etc.
RS
Sensor resistance
0.5 kΩ to 5 kΩ
Hydrogen 100 ppm/ air
β
Sensitivity slope
0.60 to 1.20
log(Rs(1000 ppm) / Rs(100 ppm))
log(1000/100)

Standard Test Conditions:
Temp: 20°C ± 2°C
Humidity:65% ± 5%
(in clean air)
VC : 10.0 V ± 1% 
VH : 5.0 V ± 1%  
RL : 3.9 kΩ ± 5%
Pre-heating time: more than 48 hours
Mechanical characteristics
Items
Conditions
Specifications
Vibration
Frequency:
Vertical amplitude:
Duration:
100 cpm
4 mm
1 hour
Should satisfy the
specifications shown in the
sensitivity characteristics.

Shock
Acceleration:
Number of impacts:
100 G
5 times

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service