Tin Dioxide Semiconductor Gas Sensor for Air Quality Controls - SP3S-AQ2-01
• Target gas: Carbon monoxide/VOC/Alcohol
• Operating temperature: 0°C to 40°C
• Storage temperature: -10°C to 70°C
• Relative humidity: Less than 95% RH
• Sensor resistance: 5kΩ to 20kΩ
• Sensitivity slope: 0.15 to 0.45
• Air quality control/Automobile
- Quantity:
- - +
Product Specification
SP3S-AQ2-01 Tin Dioxide Semiconductor Gas Sensor Description
The SP3S-AQ2-01 series is a tin dioxide semiconductor gas sensor which has a high sensitivity to various air pollution sources (e.g.VOCs) with quick response speed.
This series uses a compact plastic housing with 3 pins configuration achieving an excellent gas sensing performance with low cost.This model is ideal for various design of automatic air quality control systems ; Ventilation Fans , air purifiers.
SP3S-AQ2-01 Tin Dioxide Semiconductor Gas Sensor Application
• Air quality control
• Automobile
SP3S-AQ2-01 Tin Dioxide Semiconductor Gas Sensor Specifications
Standard Operating conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
VH |
Heater voltage |
5.0 V ± 4% |
AC or DC |
VC |
Circuit voltage |
5.0 V ± 4% |
AC or DC |
RL |
Load resistance |
Variable |
PS < 15 mW |
RH |
Heater resistance |
86 Ω ± 5% |
at room temperature |
PH |
Heater power consumption |
210mW (Typical value) |
PH = VH2/RH |
PS |
Power dissipation of sensing element |
Less than 15 mW |
PS = (VC - VRL)2/RS |
Environmental conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
Tao |
Operating temperature |
0°C to 40°C |
Recommended range |
Tas |
Storage temperature |
-10°C to 70°C |
|
RH |
Relative humidity |
Less than 95% RH |
|
(O2) |
Oxygen concentration |
21% (Typical value) |
Absolute minimum level: more than 18% |
The sensitivity characteristics are influenced by the variation in oxygen concentration. |
|||
Sensitivity characteristics |
|||
Model |
SP3S-AQ2-01 |
||
Symbol |
Parameter |
Specification |
Conditions etc. |
RS |
Sensor resistance |
5kΩ to 20kΩ |
in air |
β |
Sensitivity slope |
0.15 to 0.45 |
RS in 10ppm hydrogen/Rs in air |
Standard Test Conditions: |
Temp: 20°C ± 2°C Humidity:65% ± 5% (in clean air) |
VC : 5.0 V ± 1% VH : 5.0 V ± 1% RL : 10 kΩ ± 5% |
|
Pre-heating time: more than 48 hours |
|||
Mechanical characteristics |
|||
Items |
Conditions |
Specifications |
|
Vibration |
Frequency: Vertical amplitude: Duration: |
100 cpm 4 mm 1 hour |
Should satisfy the specifications shown in the sensitivity characteristics. |
Shock |
Acceleration: Number of impacts: |
100 G 5 times |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Long life electrochemical oxygen sensor (O2 sensor )
-
Air quality sensor VOC sensor
-
VOC Air quality sensor Formaldehyde sensor
-
Combustible gas sensor Natural Gas sensor TGS2611
-
Flammable gas sensor Liquefied petroleum gas sensor TGS2610
-
Methane and LP Gas sensor
-
Methane and LP Gas sensor
-
Alcohol sensor
-
Combustible Gases sensor
-
Hydrogen Gas Sensor