Submersible H2S/Sulphide Probe - H2S/Sulphide Probe
- Sensors for H2S (amperometric micro-sensor), temperature, pH and depth
- Very easy sensor exchange
- Very small dimensions (48 mm diameter, 440 mm total length)
- Low weight of 1 kg
- Small and low-weight cable (6 mm diameter)
- Low running costs for chemical sensor replacement
- Quantity:
- - +
Product Specification
Submersible H2S/Sulphide Probe
In-situ measurements and profiling in shallow water
Accurate - Reliable - Small Dimensions - Easy Handling
The determination of total dissolved sulphide (sum of dissolved H2S, HS- and S2-) is one of the most important parameters for the analysis of natural waters and waste water in industry.
It is necessary to observe the total sulphide concentration, dissolved in water, to avoid any danger because of the evaporation of the very toxic H2S. H2S is able to block oxygen transporting enzymes leading to the death because of inner suffocation. On the other hand, the total dissolved sulphide concentration is an interesting parameter for scientists of several scientific departments. They use this parameter for the assessment of natural lakes, but also for instance to understand volcanic activities.
But due to a lot of the hydrogen sulphide’s inconvenient chemical properties, like high chemical reactivity, very fast oxidation in the presence of oxygen and the fast concentration exchange between the liquid sample and the gaseous phase above (mostly air), the determination is difficult. Even though the sampling and the determination have been done very carefully, the results are uncertain and mostly disappointing.
All these disadvantages could be avoided, if the new Submersible H2S/Sulphide Probe is used for accurate and reliable the in-situ determination in depths of up to 100 m.
Submersible H2S/Sulphide Probe Special Features:
- Sensors for H2S (amperometric micro-sensor), temperature, pH and depth
- Very easy sensor exchange
- Windows based software for display of chemical/physical units and diagrams
- Free selection of displayed parameters (H 2 S or total dissolved sulphide, T, pH)
- Titanium made housing and protection cage
- Subconn titanium connector
- Very small dimensions (48 mm diameter, 440 mm total length)
- Low weight of 1 kg
- Small and low-weight cable (6 mm diameter)
- Low running costs for chemical sensor replacement
Standard Sensor Equipment
Sensors |
Principle |
Range |
Accuracy |
Resolution |
Response time |
Pressure |
piezo-resistive full bridge |
10 bar |
± 0,1 % FS |
0,002 % FS. |
150 ms |
Temperature |
Pt 100 |
- 2 ... + 36 °C |
± 0,05 °C |
0,0006 °C |
1 s |
pH |
single rod electrode |
0 ... 14 pH |
± 0,02 pH |
0,0002 pH |
1 s |
H2S |
Amperometric
micro-sensor
|
10µg/l...3mg/l
50µg/l..10mg/l
500µg/l..50mg/l
|
2% of reading |
< 0,1% |
<1 s |
Technical data of the probe system
Feature |
Online Probe |
Memory Probe |
Dimensions: |
Ø 48, length: 400 mm |
Ø 48, length: 440 mm |
Weight on air: |
1.1 kg |
1.3 kg |
Material: |
Titanium |
Titanium |
Connector: |
Subconn MCBH4M |
Subconn MCBH5M |
Power Supply: |
External 9...30 Volt DC |
External: 7...16 V DC Internal Battery: 1...5 V DC |
Current consumption: |
12 mA at 12 V DC |
External power supply: 15 mA Li-battery (3,6 V): approx. 20...35 mA Alk.-battery (1,5 V): approx. 50...90 mA |
Data output |
Serial port RS232, option: FSK-telemetry |
Serial port RS232 |
Memory capacity: |
none |
8 MB (approx. 350.000 data sets) |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Laboratory Dissolved Oxygen Sensor
-
Submersible Galvanic Dissolved Oxygen Sensor
-
UVT-LED Sensor UV Transmittance Sensor
-
4-20mA Dissolved Oxygen Transmitters
-
Dissolved Oxygen Sensor for Oxygen Measurement
-
Memosens Oxygen Sensor
-
Dissolved Oxygen Sensor
-
Optical Oxygen Sensor
-
Integrated Blue-green Algae Sensor
-
Integrated Water and Oil Sensor