Secondary Standard Pyranometer - MS-80
• ISO 9060
• Fastest Detector Response
• Lowest Temperature Coefficient
• Lowest Offsets A And B
• Industrial Sensor Outputs
• 5 Year Warranty and Recommended Recalibration
• Non-stability (change/5 years): +/- 0.5%
• Non-linearity (at 1000W/m²): +/- 0.2%
• Operating temperature range: -40 to +80 °C
- Quantity:
- - +
Product Specification
MS-80 Pyranometer Description
EKO’s new generation sensors broke with the rules of traditional pyranometer architecture. The innovative patented design was inspired by the combination of latest technologies and state-of-the-art thermopile sensor, enabling a breakthrough in unprecedented low zero-offset behaviour and fast sensor response.The compact sensor with single dome is immune to offsets and integrates all value added functions such as a ventilator, heater and different industrial interfaces.
The MS-80A is an MS-80 with built in 4-20mA converter and MS-80M with buit in MODBUS converter are compatible to the industrial output standards. Due to the ultra low temperature dependency and exceptional non-linearity characteristics, the converter guarantees an optimal sensor performance, under any environmental conditions. The MS-80 pyranometers are manufactured in a consistent way followed by strict quality inspection and performance evaluation. For each sensor the directional response and temperature dependency are measured and validated through a measurement report that comes with the sensor.
EKO provides a unique calibration compliant to the international standards defined by ISO/IEC17025 / 9847. The sensor has 5 year warranty, 5 years recommended re-calibration interval and no longer need to change the dessicant.
MS-80 Pyranometer Features
• ISO 9060
• Fastest Detector Response
• Lowest Temperature Coefficient
• Lowest Offsets A And B
• Industrial Sensor Outputs
• 5 Year Warranty and Recommended Recalibration
MS-80 Pyranometer Specifications
Specifications (typical) |
MS-80 |
MS-80A |
MS-80M |
Output |
mV |
4-20mA |
MODBUS |
ISO 9060 classification |
Secondary Standard |
Secondary Standard |
Secondary Standard |
Response time 95% (sec) |
< 0.5 |
< 1.5 |
< 1 |
Zero offset - Thermal radiation (200W/m²) |
< 1 W/m² |
< 1 W/m² |
< 1 W/m² |
Zero offset - Temperature change (5K/hr) |
+/- 1 W/m² |
+/- 1 W/m² |
+/- 1 W/m² |
Non-stability (change/5 years) |
+/- 0.5% |
+/- 0.5% |
+/- 0.5% |
Non-linearity (at 1000W/m²) |
+/- 0.2% |
+/- 0.2% |
+/- 0.2% |
Directional response (at 1000W/m²) |
< 10 W/m² |
< 10 W/m² |
< 10 W/m² |
Spectral selectivity (0.35-1.5µm) |
+/- 3% |
+/- 3% |
+/- 3% |
Temp. response (for 70°C band) |
< 1% |
< 0.4% |
< 0.4% |
Tilt response (at 1000W/m²) |
+/- 0.2% |
+/- 0.2% |
+/- 0.2% |
Sensitivity (µV/W/m²) |
Approx. 10 |
1mA / 100 W/m2 |
- |
Impedance (Ω) |
Approx. 45kΩ |
- | - |
Operating temperature range (°C) |
-40 to +80 |
-40 to +80 |
-40 to +80 |
Irradiance range (W/m²) |
0 - 4000 |
0 - 4000 |
0 - 4000 |
Cable length |
10m |
10m |
10m |
Wavelength range in nm |
285 to 3000 |
285 to 3000 |
285 to 3000 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Industrial Grade Solar Sensor
-
Photosynthetically Active Radiation (PAR) Sensor
-
Illuminance Sensors LUX Sensor
-
ISO First Class Pyranometer
-
First Class Pyranometer
-
Smallest True Thermopile Pyranometer
-
Compact All Weather Spectroradiometer
-
New Generation Grating Spectroradiometer
-
Secondary Standard Pyranometer
-