New Generation Grating Spectroradiometer - MS-711

  • New Generation Grating Spectroradiometer
  • New Generation Grating Spectroradiometer
Mouse over image to zoom

• Wavelength range: 300 to 1100 nm
• Wavelength interval: 0.3 - 0.5nm
• Optical resolution FWHM: < 7nm
• Wavelength accuracy: +/- 0.2 nm
• Operating temperature: -10 to 50ºC
• Exposure time: 10msec - 5sec Automatic adjustment

  • Model Number: MS-711
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

MS-711 Spectroradiometer Description
The new generation grating spectroradiometer MS-711 is designed to provide the most accurate solar spectral data outdoors. The MS-711 is a unique all weather sensor, without any moving parts. The detector core is temperature controlled to provide accurate irradiance measurement data within the spectral range from 300nm to 1100nm (UV / Visible / NIR).

MS-711 is accurately calibrated with traceability to the International Standards and issued with a calibration uncertainty budget. The rugged optical design of the diffusor and input optics make the MS concept superior to any fiber optic spectroradiometer which will be susceptible to mechnical vibration and handling. The MS spectroradiometers are designed for permanent installation, but are perfectly suited as a traveling reference.

MS-711 has a separate power supply unit and can be controlled through RS232 / 422 by a PC or data logger. The PC software provides different functions for operating, data management and visualisation. Through the open command protocol of the defined system control functions, software can be developed by the individal user. Measuring spectral irradiance is a must to understand the effect of the non-uniform energy distribution of the sun. Since the solar spectrum varies as a function of air-mass and composition of the atmosphere, the MS-711 reveals those details. While thermopile pyrheliometers and pyranometers are most suitable to quantify the total DNI or global radiation (W/m2), spectroradiometers give detail about the energy distribution (W/m2/nm), which is most important for PV or CPV cell research and performance analysis.

MS-711 Spectroradiometer Features
• New Reference For Spectral UV - VIS - NIR
• High Optical Resolution <7nm
• Extended Operating Temperature Range -10 to 50°C
• Made For Outdoor Solar Research
• Robust Design No Moving Parts

MS-711 Spectroradiometer Specifications

Specifications (Typical)
MS-711
Wavelength range
300 to 1100 nm
Wavelength interval
0.3 - 0.5nm
Optical resolution FWHM
< 7nm
Wavelength accuracy
+/- 0.2 nm
Cosine Response (Zenith: 0 ~ 80°)
< 5 %
Temp. dependency (-10ºC to 50°C)
< 2 %
Temp. control
25ºC ± 2ºC
Operating temperature
-10 to 50ºC
Exposure time
10msec - 5sec Automatic adjustment
Dome material
Synthetic Quartz Glass
Communication
RS-422 (Between sensor and power supply)
Power requirement
12VDC, 50VA (from the power supply)
Dimension
Diameter 220 x Height 197mm
Weight
4.5 kg


Power Supply
Input
AC100-240V, 50/60Hz, 50VA
Output
DC12V
Communication
RS-232C (Between power supply and PC)
Operating Environment 
Temperature: -10 to 40°C, Hunidity: 0 to 90 %RH
*No condensation
Dimension
320 (W) x 240 (D) x 80 (H)
Weight
1kg

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service