Refrigerant/SF6 Gas Leak Detector - AR5750B

  • Refrigerant/SF6 Gas Leak Detector
  • Refrigerant/SF6 Gas Leak Detector
Mouse over image to zoom

• Detect item​: All halogen gas​
• Sensitivity​: Halogen refrigerant gas 3gr / yr​
• Response time​: Instantaneous​
• Warm up time​: < 6 second​
• Continuous operation time​: 5 hours(slightly vary with operation)​
• Operation temperature​: 0 to 52℃( 0 to 110℉)​
• Power supply​: 2000mAh, 3.7V lithium rechargeable battery​

  • Model Number: AR5750B
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

AR5750B Refrigerant/SF6 Gas Leak Detector Description
A gas detector is a device that detects the presence of gases in an area, often as part of a safety system. This type of equipment is used to detect a gas leak and interface with a control system so a process can be automatically shut down. A gas detector can sound an alarm to operators in the area where the leak is occurring, giving them the opportunity to leave. This type of device is important because there are many gases that can be harmful to organic life.

Gas detectors can be used to detect combustible, flammable and toxic gases, and oxygen depletion, etc. This type of device is widely used in industry and can be found in locations, such as on oil rigs, to monitor manufacture processes and emerging technologies such as photovoltaic. They may also be used in firefighting.

This rechargeable refrigerant gas detector respond to all halogenated refrigerant, but also apply to:
A. This was response to all halogenated refrigerant (including chlorine and fluoride). Including but not only limited to below:
    CFCs      e.g. R12, R11, R500, R503 etc…
    HCFCs   e.g. R22, R123, R124, R502 etc…
    HFCs      e.g. R134a, R404a, R125 etc…
    Also can detect compound gas for example AZ-50, HP62, Mp39, etc…
B. Detect  gas leaks in hospital equipments.
C. SF6 gas was detected in high voltage circuit shot cut..
D. Detect halogen gas when gas mixing with, chlorine, fluorine,bromine.
E. Detect carbon tetrachloride from the dry cleaning machine.
F. Detect the halon gas from the fire extinguisher.

AR5750B Refrigerant/SF6 Gas Leak Detector Specifications

Detect item
All halogen gas
Sensitivity
Halogen refrigerant gas 3gr / yr
Response time
Instantaneous
Warm up time
< 6 second
Continuous operation time
5 hours(slightly vary with operation)
Low battery indiction
3.3V±0.2V
Operation temperature
0 to 52℃( 0 to 110℉)
Power supply
2000mAh, 3.7V lithium rechargeable battery
Weight/Size
405g ; 235 x 86 x 46 mm
Standard accessory
PP box * 1
Power Adapter ( DC5V 500mA )*1
Sensing tip