Oxygen Sensor - PSR-11-917-J
USA manufactured and medical certified electrochemical galvanic oxygen sensors with excellent accuracy and stability and individually tested prior to shipment.
Fresh sensors direct from manufacturing with extended lifetimes and long warranty.
- Quantity:
- - +
Product Specification
USA manufactured and medical certified electrochemical galvanic oxygen sensors with excellent accuracy and stability and individually tested prior to shipment.
Fresh sensors direct from manufacturing with extended lifetimes and long warranty.
Compliant to FDA, MDSAP, ISO13485, ISO9001
Contact us for pricing and quantity discounts.
Technical Specifications:
Measuring Range |
0-100% O2 |
Signal Output (1) |
7-14 mV |
Response Time 90% |
13 Seconds |
Accuracy Full Scale (2) |
±1% |
Accuracy FS Over Operating Range (3) |
±5% |
Drift % Signal Month (2) |
< 1% |
Linearity (2) |
±1% |
Humidity Non-Condensing |
0-99% RH |
Temperature Coefficient |
Compensated |
Operating Temperature |
0-45℃ |
Operating Pressure |
Constant 5-30 PSIG |
Flow Rate |
.1-10 LPM |
Expected Life (1) |
60 Months |
Storage (4) |
0 to 40℃ |
Warranty (5) |
18 Months |
Electrical Connections |
Phono Plug |
Packaging |
Polyetylene bag in 3" x 3" x 1.5" paper box |
Recommended Storage |
< 6 months |
(1)In air @ 25℃and 1 atm. Expected life varies inversely with changes in O2 concentration, temperature, pressure.
(2)Under constant conditions. Calibrate as near sample conditions as possible. Calibrate with 95-100% oxygen for measurements > 40% oxygen.
(3)Once the signal output stabilizes following a step change in temperature.
(4)Recommended 0-40℃. Sensors may be stored at -10 to 55℃ on an intermittent basis only.
(5)Ex-factory unless agreed to in writing. Under normal application conditions sensor is warranted to be free of defects in material and workmanship for the period specified above proved the sensor is properly installed and operated. Analytical Industries Inc. shall not be liable for buyer's negligence,misapplication, alteration or abuse. The sole remedy for a sensor determined to be defective by Analytical Industries Inc. is limited to replacing the defective sensor.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Oxygen Analyzer
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Oxygen(O2)Gas Sensor
-
Oxygen(O2)Gas Sensor
-
High Quality O2 Sensors