Nephelometric Turbidity & Temperature Sensor - NTU
• Measurement principle: Diffusion IR at 90°
• Range: 0-4000 NTU or 0-4500 mg/L
• Resolution: 0,01 to 1 NTU - mg/L
• Accuracy: < 5% of the reading
• Temperature compensation: via CTN
• Operating temperature: -10°C to + 60°C
• Signal interface: Modbus RS-485 (standard) and SDI-12 (option)
• Sensor power-supply: 5 to 12 volts
- Quantity:
- - +
Product Specification
NTU Nephelometric Turbidity & Temperature Sensor Optical technology :
The measure principle is based on IR nephelometry / 880 nm (ISO 7027). The sensor can be calibrated with a formazine standard solution.
The NTU sensor integrates a low-cost optical technology, with a very few maintenance and no consumables.
NTU Nephelometric Turbidity & Temperature Sensor Digitally optimised measurement technology
• IR optical sensor with optical fibre
• Range: 0-4000 NTU or 0-4500 mg/L
• Digital sensor: Modbus RS-485
• ISO 7027 compliant
• Robust and waterproof
NTU Nephelometric Turbidity & Temperature Sensor Applications
• Industrial effluent treatment
• Urban waste water treatment
• Surface water monitoring
• Drinking water
• Sanitation network
NTU Nephelometric Turbidity & Temperature Sensor Specifications
Measurement |
|
Measurement principle |
Diffusion IR at 90° |
Measured ranges |
0 to 4000 NTU in 5 ranges: 0 - 50 NTU, 0 - 200 NTU, 0 - 1000 NTU, 0 - 4000 NTU, 0 to 4500 mg/L. Calibration: Range 0-500 mg/L according to NF EN 872 Range >500 mg/L according to NF T 90 105 2 AUTOMATIC |
Resolution |
0,01 to 1 NTU - mg/L |
Accuracy |
< 5% of the reading |
Temperature compensation |
via CTN |
Operating temperature |
-10°C to + 60°C |
Signal interface |
Modbus RS-485 (standard) and SDI-12 (option) |
Maximum refreshing time |
< 1 second |
Sensor power-supply |
5 to 12 volts |
Electric consumption |
Standby: 40 μA, Average RS485 (1 measure/second): 820 μA, Average SDI12 (1 measure/second) : 4.2 mA |
Sensor |
|
Dimensions |
Diameter: 27 mm; length: 170 mm |
Weight |
300 g (sensor + cable 3 metres) |
Material |
PVC, Quartz, PMMA, Nickel-plated brass |
Maximum pressure |
5 bars |
Connection |
9 armoured connectors, polyurethane jacket, bare-wires or waterproof Fisher |
Degree of protection |
IB68 up to gland |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Laboratory Dissolved Oxygen Sensor
-
Submersible Galvanic Dissolved Oxygen Sensor
-
UVT-LED Sensor UV Transmittance Sensor
-
4-20mA Dissolved Oxygen Transmitters
-
Dissolved Oxygen Sensor for Oxygen Measurement
-
Memosens Oxygen Sensor
-
Dissolved Oxygen Sensor
-
Optical Oxygen Sensor
-
Integrated Blue-green Algae Sensor
-
Integrated Water and Oil Sensor