MLV Series Low Voltage Pressure Sensors - MLV-L01D/MLV-005D
• 1 inH2O to 150 PSI Pressure Ranges
• Supply Voltage: 12 Vdc
• Lead Temperature (soldering 2-4 sec.): 270 °C
• Compensated Temperature: 0°C to 50°C
• Operating Temperature: -25°C to 85 °C
• Storage Temperature: -40°C to 125 °C
• Humidity Limits: 0 to 95% RH (non condensing)
- Quantity:
- - +
Product Specification
MLV Series Low Voltage Pressure Sensors General Description
The MLV Series Compensated Sensor is based on All Sensors' CoBeam Technology. The device provides a high output signal at a low operating voltage while maintaining comparable output levels to traditional equivalent compensated millivolt sensors operating at higher voltages. This lower supply voltage gives rise to improved warm-up shift while the CoBeam2 TM Technology itself reduces package stress susceptibility resulting in improved overall long term stability. The technology also vastly improves position sensitivity compared to conventional single die devices.
These calibrated and compensated sensors give an accurate and stable output over a wide temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. A protective parylene coating is optionally available for moisture/harsh media protection. The output is also ratiometric to the supply voltage and designed to operate at 5.0 volts DC.
MLV Series Low Voltage Pressure Sensors Features
• 1 to 30 inH2O & 5 to 150 PSI Pressure Ranges
• 5V Operation
• High Output
• Low Power Consumption
• Excellent Position Sensitivity
• Low Warm-Up Shift
• Enhanced Front to Back Linearity
• Protective Parylene Coating Option
MLV Series Low Voltage Pressure Sensors Applications
• Medical Breathing
• Environmental Controls
• HVAC
• Industrial Controls
• Portable/Hand-Held Equipment
MLV Series Low Voltage Pressure Sensors
Pressure Sensor Maximum Ratings |
|
Environmental Specifications |
||
Supply Voltage (Vs) |
12 Vdc |
Temperature Ranges |
|
|
Common Mode Pressure |
|
Compensated |
0°C to 50°C |
|
InH2O Devices (L01, L02, L05, L10, L20, L30) |
10 psig |
Operating |
-25°C to 85 °C |
|
PSI Devices (005, 015, 030, 100, 150) |
50 psig |
Storage |
-40°C to 125 °C |
|
Lead Temperature (soldering 2-4 sec.) |
270 °C |
Humidity Limits |
0 to 95% RH (non condensing) |
MLV Series Low Voltage Pressure Sensors Standard Pressure Ranges
Device |
Operating Range |
Proof Pressure |
Burst Pressure |
Nominal Span |
MLV-L01D |
±1 inH2O |
100 inH2O |
300 inH2O |
7 mV |
MLV-L02D |
±2 inH2O |
100 inH2O |
300 inH2O |
10 mV |
MLV-L05D |
±5 inH2O |
200 inH2O |
300 inH2O |
15 mV |
MLV-L10D |
±10 inH2O |
200 inH2O |
300 inH2O |
20 mV |
MLV-L20D |
±20 inH2O |
200 inH2O |
500 inH2O |
20 mV |
MLV-L30D |
±30 inH2O |
200 inH2O |
800 inH2O |
20 mV |
MLV-005D |
±5 PSI |
10 PSI |
30PSI |
25 mV |
MLV-015D |
±15 PSI |
60 PSI |
120 PSI |
37.5 mV |
MLV-015A |
0 - 15 PSIA |
60 PSI |
120 PSI |
37.5 mV |
MLV-030D |
±30 PSI |
90 PSI |
150 PSI |
37.5 mV |
MLV-100D |
±100 PSI |
200 PSI |
250 PSI |
41.67 mV |
MLV-150D |
±150 PSI |
200 PSI |
250 PSI |
37.5 mV |
MLV Series Low Voltage Pressure Sensors How To Order
A Package
Example: MLV-L02D-A6BBF-N
E Package
Example: MLV-L02D-E1ND-N
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-