Mass Flowmeter for Gases - 4040
• Fast and accurate
• Low pressure drop
• Calibration: Air, O2, N2
• Inlet/Outlet Diameter: 22 mm ISO tapered
• Flow Measurement Range: 0-300 Std L/min
• Volume Measurement Range: 0.01 - 99.9 liters
• Pressure Measurement Range: 50-199 kPa absolute
• Temperature Measurement Range: 0-50°C
• DC Power Input: 7.5 VDC ±1.5 V, 300 mA max
- Quantity:
- - +
Product Specification
4040 Mass Flowmeter PRODUCT DETAILS
The Mass Flow Meter 4040 features a 22mm ISO connection. It can be calibrated for air, oxygen, or nitrogen and has a 0-300 liter per minute range.
Whether measuring gas flows in a laboratory, hospital or clinic, or manufacturing setting, TSI general purpose mass flow meters provide accurate results and support multiple data output options. The display versions come complete with accessories, making setup and operation fast and convenient.
The TSI mass flow meters are specified as two percent of flow rate reading. One TSI mass flow meter covers the same range as three percent (or more) of full scale devices, with better accuracy at most points.
Fast four-millisecond response ensures accuracy in fluctuating flows. This fast response time is ideal for closed-loop control systems and integrated volume measurements. Low pressure drop minimizes flow circuit back pressure and its impact on the system.
4040 Mass Flowmeter FEATURES AND BENEFITS
• Range: 0-300 L/min
• Calibration: Air, O2, N2
• Connection: 22mm ISO
• Fast and accurate, 4mm response time
• Low pressure drop
4040 Mass Flowmeter APPLICATIONS
• Medical
• Industrial
• Laboratory
4040 Mass Flowmeter SPECIFICATIONS – DIGITAL DISPLAY MODELS
Model |
4040 |
|
Gas Calibration |
Air, O2 , N2 , Air/O2 Mixture |
|
Inlet/Outlet Diameter |
22 mm ISO tapered |
|
Flow Measurement |
Range |
0-300 Std L/min |
Accuracy — Air and O2 |
±2% of reading or 0.05 Std L/min, whichever is greater |
|
Accuracy — N2 |
±3% of reading or 0.1 Std L/min, whichever is greater |
|
Accuracy — Air and O2 mixture |
±3% of reading or 0.1 Std L/min, whichever is greater |
|
Accuracy — N2O |
N/A |
|
Response |
4 ms to 63% of full scale flow |
|
LCD Display Units |
L/min, Std L/min |
|
Overall Dimensions |
7.2” x 2.5” x 2.1” (182 x 63 x 53 mm) |
|
Volume Measurement |
Range |
0.01 - 99.9 liters |
Accuracy |
±2% of reading (see Operator’s Manual for additional details) |
|
Pressure Measurement |
Range |
50-199 kPa absolute |
Accuracy |
±1 kPa |
|
Response |
<4 ms to 63% of final value for step charge |
|
Temperature Measurement |
Range |
0-50°C |
Accuracy |
±1°C at flow greater than 1 Std L/min |
|
Response |
<75 ms to 63% of final value for step change |
|
Outputs |
Analog |
0-10 VDC flow only, zero and span adjustable via RS232 |
Digital |
RS232 |
|
DC Power Input |
7.5 VDC ±1.5 V, 300 mA max |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
MF4000 Series Gas Flow Meters
-
Gas Mass Flow Meters
-
MF5200 Series Oxygen Flow Meters
-
MF5600 Series Detachable Display Gas Flow Meters
-
MF5700 Series Protable Gas Flow Meters
-
Digital Oxygen Flow Meters
-
In-line Mass Flow Meters
-
Insertion Mass Flow Meters
-
Low Pressure Mass Flow Meters
-
Electromagnetic Flowmeter