Indoor Air Quality Monitor / Controller - F2000IAQ-VOC
• VOC's measuring range: 1~30ppm
• Display resolution: 0.1ppm
• Power supply: 24VAC/VDC
• Consumption: 2.8 W
• Response Time: <5 minutes for 90% step change
• Output resolution: 10Bit
• Operation temperature: 0~50°C (32~122°F)
• Operation humidity: 0~95%RH, non condensing
- Quantity:
- - +
Product Specification
Indoor Air Quality Monitor / Controller
model#: F2000IAQ-VOC
Temperature & Humidity Monitoring
• Real time detecting indoor air quality with LCD display
• High sensitivity for VOCs and other indoor contaminative gases
• 5~7 years long life
• Temperature and humidity detection and compensation
• Provide up to 1 analog output and 2 dry contact outputs
• Optional Modbus RS485 communication interface
• Strong function, high performance, low price
F2000IAQ-VOC Indoor Air Quality Monitor / Controller Description
IAQ is a comprehensive index, including room temperature, humidity, fresh air, and diverse low concentrations air contaminants. Monitoring IAQ is very important to guarantee healthy life and work.
F2000IAQ-VOC is specially designed to detect indoor air quality in offices and home environments. Its internal gas sensor has high sensitivity not only to VOC's such as toluene emitted from wood finishing and construction products but also to other air contaminants which are emitted by cigarette smoke, ammonia and H2S. It's also sensitive to carbon monoxide, alcohol, natural gas and smell from people’s body. So it is more suitable for monitoring IAQ than other sensors which one is only for one kind of gas.
F2000IAQ-VOC also can be used as a controller in ventilation system and AC system.
F2000IAQ-VOC Indoor Air Quality Monitor / Controller Features
• Real time monitor ambiance air quality with a mix gas sensor
• Japanese semiconductor gas sensor with 5~7 years long life
• Monitor temperature and relative humidity
• LCD display air quality as well as temperature and humidity, fan status etc. Makes reading and operating easy and accurate.
• user-friendly setting buttons
• Temperature and humidity compensation makes the IAQ measurement more consistent in different environments
• Modbus RS-485 communication interface optional, 15KV antistatic protection, independent base address setting
• Up to 1x0~10V analog output and 2xrelay dry-contact outputs
• Two alternatives for the analog output : linearized over full range output or PID control output.
• The relays can be selected to control IAQ , temperature or humidity (programmable setting)
• Timer of turning-off function for the ventilator device from 0.5 to 12 hours.
• Low power consumption
F2000IAQ-VOC Indoor Air Quality Monitor / Controller Application
• Ambiance air quality detection and alert
• Ventilation control
• Air quality monitors
• Odor monitors
F2000IAQ-VOC Indoor Air Quality Monitor / Controller Specifications
Gas detected |
VOCs ( toluene emitted from wood finishing and construction products); Cigarette smoke (hydrogen, carbon monoxide); ammonia and H2S, alcohol, natural gas and smell by people's body |
|
Sensing element |
Semiconductor mix gas sensor |
|
Power supply |
24VAC/VDC |
|
Consumption |
2.8 W |
|
Response Time |
<5 minutes for 90% step change |
|
Warm up time |
48 hours (first time), 1 hour (normal operation) |
|
VOC's measuring range |
1~30ppm |
|
Display resolution |
0.1ppm |
|
Temperature & Humidity Sensor |
Temperature |
Relative Humidity |
Sensing element |
NTC |
Capacitive sensor |
Measuring range |
0~50°C |
0 - 95%RH |
Accuracy |
±0.5°C (25°C, 40%-60%RH) |
±4.5%RH (25°C, 40%-60%RH) |
Display resolution |
0.5°C |
1%RH |
Stability |
±0.5°C per year |
±1%RH per year |
Analog output |
0~10VDC linear output or PID control output, programmable selection |
|
Output resolution |
10Bit |
|
Relay output |
Two dry contact outputs with programmable selection to control VOC, temperature, humidity. Rated switching current 2A(220VAC/30VDC), resistance load |
|
Modbus interface |
Modbus RS-485 protocol. 19200bps(default) 15KV antistatic protection, independent base address, 31 max network nodes |
|
Operation temperature |
0~50°C (32~122°F) |
|
Operation humidity |
0~95%RH, non condensing |
|
Storage conditions |
0~50°C (32~122°F) |
|
Net Weight |
280g |
|
Dimensions |
120mm x 90mm x 24mm |
|
Installment standard |
65mm x 65mm or 2" x 4" wire box |
|
Interface connections (Max.) |
10 terminals |
|
Wiring standard |
Wire section area <1.5mm2 |
|
Quality System |
ISO 9001 |
|
Programming and selection |
Via DIP switch and external push-buttons |
|
Outputs (max.) |
1~2 dry contact relay outputs, 1X0~10V output |
F2000IAQ-VOC Indoor Air Quality Monitor / Controller Models Guide
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether