Indoor Air Quality Detector/Controller - F2000TSM-VOC Series
• Measuring range: 1~30ppm
• Power Supply: 24VAC/VDC
• Consumption: 2.5 W
• Analog output: 0~10VDC linear output
• Output resolution: 10Bit
• Temperature range: 0~50°C (32~122°F)
• Humidity range: 0~95%RH, non condensing
- Quantity:
- - +
Product Specification
Indoor Air Quality Detector/Controller
Model#: F2000TSM-VOC Series
• Real time detect and indicate Indoor Air Quality
• High sensitivity to VOC’s and various other indoor air gases
• 5~7 years lifetime
• Temperature and humidity compensation
• Providing 1x 0~10VDC/ 4~20mA linear output for VOC measurement
• Modbus RS485 communication interface
• Providing 1x dry contact output to control a ventilator
• Featured 6 LED indicator lights indicates different IAQ levels
• The highest performance with the lowest price
F2000TSM-VOC Series Indoor Air Quality Detector/Controller Description
Its internal mixed gas sensor (normally called VOC sensor) is very sensitive to VOC concentration in the air (VOC i.e. Volatility Organic Compound, such as timber dope and toluene emitted by building materials), and other air pollutants such as cigarette smoke, ammonia and H2S. It also has high sensitivity to CO, alcohol, natural gas and odorous smells from human bodies. Compared with other single air sensor, F2000TSM-VOC series is better for longtime IAQ detection.
F2000TSM-VOC series can also be used as a controller in application of ventilation and air conditioning systems to improve indoor air quality and to achieve the best energy saving.
F2000TSM-VOC Series Indoor Air Quality Detector/Controller Features
• Wall mounting, real time detect indoor air quality
• With Japanese semiconductor mix gas sensor inside. 5~7 years lifetime.
• High sensitive to contaminative gases and various kinds of odorous gases within the room (smoke, CO, alcohol, human odor, material odor).
• Two types available: indicator and controller
• Design six indicator lights to indicate six different IAQ ranges.
• Temperature and humidity compensation makes the IAQ measurements consistent.
• Modbus RS-485 communication interface, 15KV antistatic protection, independent address setting.
• Optional one on/off output to control a ventilator/air cleaner. The user can select an IAQ measurement to turn-on the ventilator between four setpoints.
• Optional one 0~10VDC or 4~20mA linear output.
F2000TSM-VOC Series Indoor Air Quality Detector/Controller Application
• Detect Indoor Air Quality
• Can be used in houses, offices, theaters, shops, restaurants, train stations and many other places
• Automatically ventilation control
NOTE: F2000TSM-VOC detector cannot be used as a safety detector, for example, gas alert detector.
F2000TSM-VOC Series Indoor Air Quality Detector/Controller Specifications
Gas detected |
VOCs (toluene emitted from wood finishing and construction products); Cigarette smoke (hydrogen, carbon monoxide); ammonia and H2S, alcohol, natural gas and smell by people’s body. |
Sensing element |
Semiconductor mix gas sensor |
Measuring range |
1~30ppm |
Power Supply |
24VAC/VDC |
Consumption |
2.5 W |
Load (for the analog output) |
>5K |
Sensor query frequency |
Every 1s |
Warm up time |
48 hours (first time) 10 minutes(operation) |
Six indicator lights |
The first green indicator light: Best air quality The first and the second green indicator lights: Better air quality The first yellow indicator light: Good air quality The first and the second yellow indicator lights: Poor air quality The first red indicator light: Poorer air quality The first and the second indicator lights: Poorest air quality |
Modbus interface |
RS485 with 19200bps(default), 15KV antistatic protection, independent base address |
Analog output (Optional) |
0~10VDC linear output |
Output resolution |
10Bit |
Relay output (Optional) |
One dry contact output, rated switching current 2A( resistance load) |
Temperature range |
0~50°C (32~122°F) |
Humidity range |
0~95%RH, non condensing |
Storage conditions |
0~50°C (32~122°F) / 5~90%RH |
Weight |
190g |
Dimensions |
100mm x 80mm x 28mm |
Installation standard |
65mm x 65mm or 2" x 4" wire box |
Wiring terminals |
Maximum 7 terminals |
Housing |
PC/ABS Plastic fireproof material , IP30 protection class |
CE approval |
EMC 60730-1: 2000 + A1:2004 + A2:2008 Directive 2004/108/EC Electromagnetic Compatibility |
F2000TSM-VOC Series Indoor Air Quality Detector/Controller Models
ITEM |
MODEL |
DESCRIPTION |
IAQ Detector |
F2000TSM-VOC-S110C-V/A |
IAQ detector with 1X0~10VDC linear output. (Can be selected 4~20mA by jumpers) Modbus RS485 interface |
F2000TSM-VOC-S100C |
IAQ detector, Modbus RS485 interface |
|
F2000TSM-VOC-S100C-SP |
IAQ detector, Modbus RS485 interface. Power supply with a 24V/230V power adaptor |
|
F2000TSM-VOC-L110C-V/A |
IAQ transmitter with 6 LED indicator lights, 1X analog output, Modbus RS485 interface |
|
F2000TSM-VOC-L100C |
IAQ indicator with 6 LED indicator lights, Modbus RS485 communication interface |
|
F2000TSM-VOC-L100C-SP |
IAQ indicator with 6 LED indicator lights, Modbus RS485 communication interface. Power supply with a 24V/230V power adaptor |
|
IAQ Controller |
F2000TSM-VOC-L101C |
IAQ indicator/controller with 6 LED lights, One dry contact output, Modbus RS485 interface |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether