Dual O2/CO2 Monitor with 10+ Year Sensors - 99039
• Sampling Method & Range: Diffusion, 0-25% O2, 0-10,000ppm CO2
• Accuracy: ±1% of full scale
• Operating Temperature: 0 to + 55°C
• Display: ¾" backlit LCD digital display
• Sensor Type: Long life zirconium oxide sensor for O2 and NDIR for CO2
• Analog Output: Analog 4-20mA output. Selectable for either Oxygen or CO2
• Power Requirements: 24VDC 350mA
- Quantity:
- - +
Product Specification
Dual O2/CO2 Monitor with 10+ Year Sensors
Item #: 99039
Dual O2/CO2 Monitor Product Summary
This dual sensor monitor is designed for use in areas containing Helium, Argon, and/or Nitrogen, that contain CO2 as well. It includes all of the top of the line features of our air check oxygen deficiency monitor, though it monitors the level of CO2 in the room as well. It is ideal for use in environments such as breweries, beverage or other bottling plants, pharmaceutical manufacturing facilities, or grow rooms. This monitor contains a 10+ year zirconium oxide sensor.
Dual O2/CO2 Monitor Features
• No maintenance zirconium O2 cell and long life CO2 sensor
• No calibration required for oxygen
• Self-calibrating CO2 sensor
• Local backlit concentration display
• Built-in audible horn
• Built-in visual LED alarm indicators
• Alarm level 1 and 2 for O2 and CO2
• 3 year warranty
• No drift due to environmental or temperature changes
The Dual O2/CO2 Monitor is a compact gas monitoring system that's ideal for the continuous monitoring of both gases simultaneously in N2 gas storage areas, CO2 beverage gas distribution areas, confined spaces, and other locations where low oxygen levels may pose a hazard to personnel. Unlike continuously depleting electrochemical sensor cells, the Dual O2/CO2 exclusive zirconium cell and patented NDIR cell provide stable oxygen and CO2 readings even in areas where temperature, barometric pressure and humidity levels are changing. The Dual O2/CO2 oxygen sensor requires no quarterly calibration or annual maintenance and the CO2 sensor automatically adjusts to ambient levels. Just plug it in and leave it alone.
Dual O2/CO2 Monitor Specifications
Sampling Method & Range |
Diffusion, 0-25% O2, 0-10,000ppm CO2 |
Accuracy |
±1% of full scale |
Operating Temperature |
0 to + 55°C |
Display |
¾" backlit LCD digital display |
Sensor Type |
Long life zirconium oxide sensor for O2 and NDIR for CO2 |
Alarm indicators |
Built-in Audible 90dB horn Orange LED alarm indicator for CO2 Red LED alarm indicator for O2 |
Signal Outputs |
One user adjustable Alarm relay for Oxygen One user adjustable Alarm relay for CO2 Relays are rated 2 amp 24VDC / 24VAC |
Analog Output |
Analog 4-20mA output. Selectable for either Oxygen or CO2 |
Power Requirements |
24VDC 350mA |
Dimensions |
6.5 (W) x 4.5 (H) x 3.25 (D) inches; (160.1 mm x 114.3 mm x 82.5 mm) |
Weight |
1.6 lbs. (.8 kg) |
Enclosure |
Polycarbonate |
Required calibration |
None for Oxygen. None for CO2 when Auto Cal function is activated. |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether