Digital Measurement General Purpose Absolute Pressure Transducer - TD1200 Series

  • Digital Measurement General Purpose Absolute Pressure Transducer
  • Digital Measurement General Purpose Absolute Pressure Transducer
Mouse over image to zoom

• Totally digital proprietary design
• Innovative redundent sensing elements
• 24V digital output for pressure or temp switch point
• Voltage and current outputs
• 15 to 300 psia absolute pressure ranges available
• Custom pressure Ranges and outputs available
• All stainless steel welded housing
• 0.25% accuracy
• ASIC technology, no zero/span potentiometers

  • Model Number: TD1200 Series
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

The TD1200 Series Ultra High Resolution Digital Measurement, General Purpose, Absolute Pressure Transducer

TD1200 Series Absolute Pressure Transducer FEATURES
• Totally digital proprietary design
• Innovative redundent sensing elements
• 24V digital output for pressure or temp switch point
• Voltage and current outputs
• 15 to 300 psia absolute pressure ranges available
• Custom pressure Ranges and outputs available
• All stainless steel welded housing
• 0.25% accuracy
• ASIC technology, no zero/span potentiometers
• IP-69K rated seal available (high pressure wash down)
• Innovative low current consumption, ideal for custom wireless solutions
• Programable systems available for OEM/systems integrators for in-house configuring of outputs, ranges and set points to reduce inventory and lead times
• Calibration Certificates available (contact customer service)

TD1200 Series Absolute Pressure Transducer DESCRIPTION
The TD1200 Series digital/configurable (an industry first) industrial absolute pressure transducer features stability and accuracy over a wide temperature range at lower cost than competitive units typically not found in older analog designs yet is plug and play with most lower grade competitive units.

With its proprietary digital/ASIC technology, the TD1200 Series features field proven redundant sensing elements without the need for solder in resistors or trim pots that can drift over time. This provides years of excellent performance and reliability even in the harshest/demanding applications. This combined with optional 4x over pressure and the optional integrated temperature or pressure digital switch feature, makes the TD1200 Series truly an industry first and second to none.

For extreme applications where power washers are used for wash down, the TD1200 Series optional IP69K seal, another industry first, makes it ideal no matter what the environment.

With its flexible low power design and lower manufacturing costs, the TD1200 Series offers outstanding value and makes it ideal for custom wireless applications.

TD1200 Series Absolute Pressure Transducer SPECIFICATIONS

Performance

 Performance @ 25°C (77°F)

Accuracy

 0.25% BFSL - (0-15 psia range with 4-20mA outupt, 0.5% BFSL)

Overange Protection

 2x Rated Pressure

Pressure Range

 15 to 300 psia

Burst Pressure

 5x

Pressure Cycles

 >100 million

Update Time

 <=1msec

Digital Output

 Optional digital output for pressure, maintenance or temp switch point

 (not available on 4-20mA output units), max load current 20mA

Environmental Data

Temperature

 

Compensated Temperatures

 -40 to 100°C (-40 to 212°F)

Operating Temperatures

 -40 to 100°C (-40 to 212°F)

Storage

 -40 to 125°C (-40 to 250°F)

TEB

 0.9% FS

Long Term Drift

 0.2% FS/year (non-cumulative)

Shock

 100g, 11 ms, 1/2 sine

Vibration

 20g, peak, 20 to 2400 Hz

EMI/FRI Protection

 Yes

Rating

 Up to IP-69K available (high pressure wash down)

Approvals

 CE

Mechanical Configuration

Pressure Connections

 See ordering chart

Wetted Material

 17-4PH stainless steel (for other materials consult factory)

Electrical Connection

 9.4 Din, IP-69K 4 pin M12 Connector

Case

 (housing) 304 stainless steel

Electrical Data

Excitation

 4-28VDC, Typ (must be at least 0.3V above full output voltage), 7.5VDC min for 4-20mA

Output

 see ordering chart

Output Impedance

 <100 Ohms, Nominal

Current Consumption

 25mA max (current output), <5mA (voltage output)

Output Noise

 <2mV RMS

Reverse Polarity Protection

 Yes

Zero and Span Offset Tolerance

 1%

Maintenance Mode

 The maintenance mode digital output indicates 1/2 bridge failure and can be selected

 instead of pressure or temp set point with the designation“M”.

Set Point for Pressure or Temp

 For pressure, this is done by selecting a percentage of your transducer’s full range and

 this will be the set point (40% of a 1000 psi range will have the set point at 400psi)“P40”.

 For temperature, select your set point in degrees C such as 40°C (104°F) and this will

 be the set point “T40”. When set point is reached and becomes active there is a digital output on pin 4.


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service