Combustion Gas Analyzer - IMR1000

  • Combustion Gas Analyzer
  • Combustion Gas Analyzer
  • Combustion Gas Analyzer
Mouse over image to zoom

• O2 Measurement: 0 ~ 21%
• CO Measurement: 0 ~ 1000 ppm/0 ~ 4000 ppm
• CO2 Measurement: 0 ~ 30%
• Battery: > 8 hrs
• Operating Temperature: 32-104°F / 0-40°C
• Operating Humidity: 10-90% rel. humidity, non-condensing
• Power Supply: 4 x AA
• Weight: 2.2lbs / 1kg
• Dimensions: 7.9" x 1.8" x 3.5"

  • Model Number: IMR1000
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

IMR1000 Combustion Gas Analyzer
The IMR1000 is a hand held pocket size stack gas analyzer for combustion tests on boilers, burners, etc. The IMR1000-1/-2 have up to two sensors with a 2-line LCD while the IMR1000-3/-4 have a 4-line LCD and come with up to 3 sensors.

  • Up to 3 sensors
  • Small and rugged
  • Easy to operate
  • Light weight
  • Memory
  • Infrared Interface for printer
  • Protective boot with integral magnet
  • Large backlit display
  • Reliable Technology
  • Easy to service
  • Displayed parameter can be chosen


IMR1000 Combustion Gas Analyzer Measured parameters:

• Oxygen O2
• Carbon Monoxide CO
• Carbon Monoxide CO (ambient)
• Nitric Oxide NO
• Flue-Gas Temperature

IMR1000 Combustion Gas Analyzer Calculated values:
• Combustion Efficiency
• Excess Air
• Carbon Dioxide
• CO corrected to 0% O2

IMR1000 Combustion Gas Analyzer Standard

Enclosure
Rugged plastic case with protective boot and magnet
Fuels
Natural Gas, Propane, Butane, LPG, Light Oil
Measuring units
ppm, mg/m3
Service program
Check of all values
Zero point calibration
Max. 60 seconds
Battery
> 8 hrs
Languages
English, German, French, etc.
Condensation trap
Integrated filter
Operating Conditions
32-104°F / 0-40°C; 10-90% rel. humidity, non-condensing
Gas sampling probe
Thermocouple Type K;
∅ 0.25"/ 6mm;
Length 9"/220mm;
Hose 9'/3m
Power Supply
4 x AA
Weight
2.2lbs / 1kg
Dimensions
7.9" x 1.8" x 3.5" / 200 x 45 x 90mm

IMR1000 Combustion Gas Analyzer Optional

AC adapter with rechargeable batteries
Infrared printer
Soft carrying case
Hard carrying case

1000-1
O2, condensation trap, gas sampling probe, batteries, manual
1000-2
O2, CO, condensation trap, gas sampling probe, batteries, manual
1000-3
O2, CO, draft, condensation trap, gas sampling probe, batteries, manual
1000-4 O2, CO, NO, draft, condensation trap, gas sampling probe, batteries, manual


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service