Carbon Dioxide Detector / Controller for Fan Switch - F2000TSM-CO2-8013

  • Carbon Dioxide Detector / Controller for Fan Switch
  • Carbon Dioxide Detector / Controller for Fan Switch
Mouse over image to zoom

​• Power supply​: 100~240VAC​
​• Consumption​: 1.8 W Max / 230VAC​
​• CO2 measuring range​: 0~2,000ppm​
​• Accuracy@25°C(77°F), 2000ppm​: ±40ppm +3% reading​
​• Stability​: <2% of FS over life of sensor​
​• Response time​: <2 minutes for 90% step change​
​• Operation temperature: 0~50°C(32~122°F)
​• Operation humidity​: 0~95%RH, non condensing​

  • Model Number: F2000TSM-CO2-8013
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Carbon Dioxide Detector/Controller for Fan Switch
Model #: F2000TSM-CO2-8013
CE Approval


F2000TSM-CO2-8013 Carbon Dioxide Detector/Controller Features
• Real-time detecting CO2 level with wall-mounting type
• NDIR infrared CO2 module inside with four CO2 detection range selectable.
• CO2 sensor has Self-Calibration Algorithm and up to 15 years lifetime
• Six indicator lights indicate six CO2 range
• An SPDT relay output with max. 8A to control a 3-wire fan. Two CO2 setpoints selectable for the relay switch by a jumper
• A touch button for operation
• Design for control a ventilator in houses, offices, or other indoor areas
• Wide power range:100~240VAC power supply
• CE-Approval


F2000TSM-CO2-8013 Carbon Dioxide Detector/Controller Specifications

Power supply
100~240VAC
Consumption
1.8 W Max / 230VAC
CO2 sensor
Non-Dispersive Infrared Detector (NDIR)
ABC Logic Self Calibration
CO2 measuring range
0~2,000ppm
Accuracy@25°C(77°F), 2000ppm
±40ppm +3% reading
Stability
<2% of FS over life of sensor
Response time
<2 minutes for 90% step change
Warm up time for turning-on
48 hours (first time), 2 minutes (operation)
6 LED lights
From left to right:
Blue Blue Green Orange Red Red
1st blue light on as CO2 measurement≤600ppm
1st and 2nd blue lights on when 600ppm
Green light on when 800ppm
Orange light on when 1,000ppm
1st red light on when 1,500ppm
1st and 2nd red lights on as CO2 measurement >2,000ppm
Relay control
Max. switch current: 8A (load resistance) SPDT relay
Two CO2 levels selectable to control the relay by jumpers
Two CO2 level selectable
1000ppm/1500ppm
The differential is 300ppm
The shortest protection time for fan turning on/off
10 minutes
Operation conditions
0~50°C(32~122°F); 0~95%RH, non condensing
Storage conditions
0~50°C(32~122°F); 0~80%RH, non condensing
Dimensions/Net weight
100mm x 80mm x 24mm (H x W x D) /180g
Installment standard
65mm x 65mm (2" x 4") wire box
Approval
CE