BLVR Series Low Voltage Pressure Sensors - BLVR-L10D-B1NS-N
• 0 to 30 "H2O Pressure Ranges
• Low Supply Voltage: 1.8V to 3.3V
• Common Mode Pressure: 5 psig
• Lead Temperature (soldering 2-4 sec.): 270 °C
• Operating Temperature: -25 to 85 °C
• Storage Temperature: -40 to 125 °C
• Humidity Limits: 0 to 95% RH (non condensing)
- Quantity:
- - +
Product Specification
BLVR Series Low Voltage Pressure Sensors General Description
The BLVR Series Basic Sensor is based on a Dual Die Reference technology to reduce all output offset or common mode errors. It also incorporates All Sensors CoBeam Technology to reduce the overall supply voltage while maintaining comparable output levels to traditional equivalent basic sensing elements. This lower supply voltage gives rise to improved warm-up shift while the CoBeam Technology itself reduces package stress susceptibility resulting in improved overall long term stability. The technology also vastly improves position sensitivity to nearly unmeasurable levels.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output is also ratiometric to the supply voltage and is operable from 1.8 to 3.3 volts DC.
BLVR Series Low Voltage Pressure Sensors Features
• 0 to 1 "H2O to 0 to 30 "H2O Pressure Ranges
• Low Supply Voltage (1.8V to 3.3V)
• 40% Less Power Than Mini-Basic Series
• 0.3% Linearity
• Improved Front to Back Linearity
• Offset Compensated
• Superior Position Sensitivity
• Improved Warm-Up Shift Distribution
• Parylene Coating Available Upon Request
BLVR Series Low Voltage Pressure Sensors Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
• Portable / Hand Held Devices
BLVR Series Low Voltage Pressure Sensors
Pressure Sensor Maximum Ratings |
|
Environmental Specifi cations |
||
Supply Voltage (Vs) |
6 Vdc |
Operating Temperature |
-25 to 85 °C |
|
Common Mode Pressure |
5 psig |
Storage Temperature |
-40 to 125 °C |
|
Lead Temperature (soldering 2-4 sec.) |
270 °C |
Humidity Limits |
0 to 95% RH (non condensing) |
BLVR Series Low Voltage Pressure Sensors Standard Pressure Ranges
Device |
Operating Range |
Proof Pressure |
Burst Pressure |
BLVR-L01D |
±1 inH2O |
100 inH2O |
300 inH2O |
BLVR-L05D |
±5 inH2O |
200 inH2O |
300 inH2O |
BLVR-L10D |
±10 inH2O |
200 inH2O |
300 inH2O |
BLVR-L20D |
±20 inH2O |
200 inH2O |
500 inH2O |
BLVR-L30D |
±30 inH2O |
200 inH2O |
800 inH2O |
Performance Characteristics for BLVR Series Low Voltage Pressure Sensors
All parameters are measured at 3.3 volt excitation and room temperature unless otherwise specified . Pressure measurements are with positive pressure applied to port B (the only port for the single port configuration ).
Parameter |
Min |
Typ |
Max |
Units |
Notes |
Output Span |
|
|
|
|
|
L01D @ 1 inH2O |
4.5 |
8.0 |
11.5 |
mV |
4 |
L05D @ 5 inH2O |
13.5 | 24.0 | 34.5 |
mV |
4 |
L10D @ 10 inH2O |
18.0 | 32.0 | 46.0 |
mV |
4 |
L20D @ 20 inH2O |
22.0 | 38.0 | 55.0 |
mV |
4 |
L30D @ 30 inH2O |
25.0 | 42.0 | 60.0 |
mV |
4 |
Offset Voltage @ Zero Diff. Pressure |
- | - |
±8.0 |
mV |
- |
Offset Temperature Shift (0°C-70°C) |
- |
±0.1 |
- |
mV |
1 |
Offset Warm-up Shift |
- |
±10 |
±80 |
uV |
2 |
Offset Position Sensitivity (1g) |
- |
±0.2 |
- |
uV |
- |
Offset Long Term Drift (One Year) |
- |
±80 |
- |
uV |
- |
Linearity, Hysteresis Error |
- | 0.1 |
±0.3 |
%FSS |
3 |
Response Time (10% to 90% Pressure Response) |
- | 100 | - |
uS |
- |
Front to Back Linearity |
- |
0.25 |
- |
%FSS |
5 |
Temperature Effect on Resistance (0°C-70°C) |
- | 2800 |
|
ppm/°C |
- |
Temperature Effect on Span (0°C-70°C) |
- |
-1900 |
- |
ppm/°C |
- |
Input Resistance |
- |
1.5 |
- |
k ohm |
- |
Output Resistance |
- |
1.5 |
- |
k ohm |
- |
BLVR Series Low Voltage Pressure Sensors How To Order
Example: BLVR-L10D-B1NS-N
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃