BLCR Series Low Voltage Pressure Sensors General Description
The BLCR Series Basic Sensor is based on a Dual Die Reference technology to reduce all output offset or common mode errors. It also incorporates All Sensors' CoBeam Technology to reduce overall supply voltage while maintaining comparable output levels to traditional equivalent basic sensing elements. This lower supply voltage gives rise to improved warm-up shift whilte the CoBeam technology itself reduces package stress susceptibility resulting in improved overall long term stability. The technology also vastly improves position sensitivity to nearly unmeasurable levels.

This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output is also ratiometric to the supply voltage and is operable from 1.8 to 3.3 volts DC. 

BLCR Series Low Voltage Pressure Sensors Features
• 0 to 1 inH2O to 0 to 30 inH2O Pressure Ranges
• Low Supply Voltage (1.8V to 3.3V)
• 0.1% Linearity Typical
• Improved Front to Back Linearity
• Intrinsically No Position Sensitivity
• Improved Warm-Up Shift Distribution
• Parylene Coating Available Upon Request
• Reduced TCO

BLCR Series Low Voltage Pressure Sensors Applications
• Medical Instrumentation
• Environmental Controls
• HVAC

BLCR Series Basic Low Voltage Pressure Sensors

Pressure Sensor Maximum Ratings

Environmental Specifications
Supply Voltage (Vs)
5 Vdc
Operating Temperature
-25 to 85 °C
Common Mode Pressure
5 psig
Storage Temperature
-40 to 125 °C
Lead Temperature (soldering 2-4 sec.)
270 °C
Humidity Limits
0 to 95% RH (non condensing)

BLCR Series Low Voltage Pressure Sensors Standard Pressure Ranges
Device
Operating Range
Proof Pressure
Burst Pressure
BLCR-L01D
±1 inH2O (249 Pa)
100 inH2O (25 KPa)
150 inH2O (37 KPa)
BLCR-L05D
±5 inH2O (1,245 Pa)
200 inH2O (50 KPa)
300 inH2O (75 KPa)
BLCR-L10D
±10 inH2O (2,491 Pa)
200 inH2O (50 KPa)
300 inH2O (75 KPa)
BLCR-L20D
±20 inH2O (4,982 Pa)
200 inH2O (50 KPa)
500 inH2O (125 KPa)
BLCR-L30D
±30 inH2O (7,472 Pa)
200 inH2O (50 KPa)
800 inH2O (200 KPa)

Performance Characteristics for BLCR Series Low Voltage Pressure Sensors
All parameters are measured at 3.3  volt excitation and room temperature unless otherwise specified. Pressure measurements are with positive pressure applied to port B ( the only port for the single port configuration ).
Parameter
Min
Typ
Max
Units
Notes
Output Span (FSS)




4
    L01D
4.5
8.0
11.5 mV

    L05D
13.5
24.0 34.5 mV

    L10D
18.0
32.0 46.0 mV

    L20D
22.0
38.0 55.0 mV

    L30D
25.0
42.0 60.0 mV

Offset Voltage @ Zero Diff. Pressure
- - ±10.0
mV
-
Offset Temperature Shift (0°C-70°C)
- ±4.0
- μV/°C
1
Offset Warm-up Shift
- ±10.0
- μV
2, 6
Offset Position Sensitivity (1g)
- ±0.2
- μV
-
Linearity, Hysteresis Error
- 0.10
±0.50
%FSS
3
Response Time (10% to 90% Pressure Response)
- 100
- μS
-
Front to Back Linearity
- 0.25
- %FSS
5
Temperature Effect on Resistance (0°C-70°C)
- 2800
- ppm/°C
-
Temperature Effect on Span (0°C-70°C)
- -2000
- ppm/°C
-
Input Resistance
- 1.7
- k Ω
-
Output Resistance
- 1.7
- k Ω
-

BLCR Series Low Voltage Pressure Sensors How To Order

Where:
Pressure Range (D1, D3, D4 Packages — Differential Only): L01D, L05D, L10D, L20D, L30D
Pressure Range (U1, U2 Package — Gage Only): L01D, L05D, L10D, L20D, L30D