BDS Series Basic Pressure Sensor - BDS-L10D030A-N9
• Supply Voltage: 6 Vdc
• Lead Temperature (soldering 2-4 sec.): 270°C
• Operating Temperature: -25 to 85 °C
• Storage Temperature: -40 to 125 °C
• Humidity Limits: 0 to 95% RH (non condensing)
• Dual Sensing Elements (Absolute & Differential)
• Gas Flow Measurement
- Quantity:
- - +
Product Specification
BDS Series Pressure Sensor General Description
The BDS Basic Pressure Sensor was designed with the idea of combining two sensing elements into one package. This sensor is designed to provide a precise fl ow measurement by combining a differential and absolute sensing element in the same package. By combining the differential and absolute sensing element, engineers can save cost and space in today's smaller devices.
The BASIC series pressure sensors are based upon a proprietary technology to reduce the size of the sensor and yet maintain a high level of performance. Output offset errors due to position sensitivity; packaging stress and long term drift are all signifi cantly reduced when compared to conventional silicon sensors. In addition, the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage.
BDS Series Pressure Sensor Features
• Dual Sensing Elements (Absolute & Differential)
• Top constraint absolute sensing element for helium applications
• Parylene coating available upon request
• RoHS Compliant
BDS Series Pressure Sensor Applications
• Gas Flow Measurement
BDS Series Basic Pressure Sensor
Pressure Sensor Characteristics Maximum Ratings |
|
Environmental Specifi cations |
||
Supply Voltage |
6 Vdc |
Operating Temperature |
-25 to 85 °C |
|
Lead Temperature (soldering 2-4 sec.) |
270°C |
Storage Temperature |
-40 to 125 °C |
|
|
|
Humidity Limits |
0 to 95% RH (non condensing) |
BDS Series Pressure Sensor Standard Pressure Range
Device Type |
Operating Pressure |
Nominal |
Std Dev. |
Units |
Proof Pressure |
Burst Pressure |
BDS-L10D030A |
-- |
-- |
-- |
-- |
-- |
-- |
Absolute |
0 - 30 PSIA |
7.5 |
±1.25 |
mV/PSI |
90 PSI |
150 PSI |
Differential |
0 - 10 inH2O |
3.0 |
±0.40 |
mV/inH2O |
15 PSI |
30 PSI |
BDS-L10D100A |
-- |
-- |
-- |
-- |
-- |
-- |
Absolute |
0 - 100 PSIA |
3.0 |
±0.28 |
mV/PSI |
150 PSI |
150 PSI |
Differential |
0 - 10 inH2O |
3.0 |
±0.40 |
mV/inH2O |
15 PSI |
30 PSI |
BDS Series Pressure Sensor Ordering Information
Part Number |
Confi guration |
||
Differential Sensor |
Absolute Sensor |
Package |
|
BDS-L10D030A-N9 |
10 inH2O |
30 PSIA |
N9 |
BDS-L10D100A-N9 |
10 inH2O |
100 PSIA |
N9 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃