• CO2 detection with 0~2000ppm range
• 0~5000ppm/0~50000ppm range selectable
• CO2 Accuracy: ±30ppm + 3% of reading @22°C
• Temperature dependence: 0.2% FS per °C
• Stability: <2% of FS over life of sensor
• Power supply: 24VAC/VDC±10%
• Consumption: 2.2 W max. ; 1.6 W avg.
• Operation temperature: 0~50°C (32~122°F)
• Operation humidity: 0~95%RH, non condensing
- Quantity:
- - +
Product Specification
BACnet Carbon Dioxide (CO2) Detector/Transmitter
with Temperature and RH% Option
Model#: G01-CO2-N10C/30C
G01-CO2-N10C/30C Carbon Dioxide Detector/Transmitter Features
• BACnet communication
• CO2 detection with 0~2000ppm range
• 0~5000ppm/0~50000ppm range selectable
• NDIR infrared CO2 sensor with More than 10 years lifetime
• Patented self-calibration algorithm
• Optional temperature and humidity detection
• Provide up to 3xanalog linear outputs for measurements
• Optional LCD display of CO2 and temperature and humidity
• 24VAC/VDC power supply
• EU standard and CE-approval
G01-CO2-N10C/30C Carbon Dioxide Detector/Transmitter Specifications
CO2 Measurement | ||
Sensing element |
Non-Dispersive Infrared Detector (NDIR) |
|
CO2 range |
0~2000ppm 0~5,000ppm/0~50,000ppm optional |
|
CO2 Accuracy |
±30ppm + 3% of reading @22°C(72°F) |
|
Temperature dependence |
0.2% FS per °C |
|
Stability |
<2% of FS over life of sensor (15 year typical) |
|
Pressure dependence |
0.13% of reading per mm Hg |
|
Calibration |
ABC Logic Self Calibration Algorithm |
|
Response time |
<2 minutes for 90% step change typical |
|
Signal update |
Every 2 seconds |
|
Warm-up time |
2 hours (first time) / 2 minutes (operation) |
|
|
Temperature |
Humidity |
Measuring range |
0°C~50°C(32°F~122°F) (default) |
0 -100%RH |
Accuracy |
±0.4°C (20°C~40°C) |
±3%RH (20%-80%RH) |
Display resolution |
0.1°C |
0.1%RH |
Stability |
<0.04°C/year |
<0.5%RH/year |
General Data |
||
Power supply |
24VAC/VDC±10% |
|
Consumption |
2.2 W max. ; 1.6 W avg. |
|
Analog outputs |
1~3 X analog outputs 0~10VDC(default) or 4~20mA (selectable by jumpers) 0~5VDC (selected at placing the order) |
|
Operation conditions |
0~50°C (32~122°F); 0~95%RH, non condensing |
|
Storage conditions |
10~50°C (50~122°F) 20~60%RH |
|
Net Weight |
250g |
|
Dimensions |
130mm(H) x 85mm(W) x 36.5mm(D) |
|
Installation |
wall mounting with 65mm x 65mm or 2" x 4" wire box |
|
Housing and IP class |
PC/ABS fireproof plastic material, protection class: IP30 |
|
Standard |
CE-Approval |
G01-CO2-N10C/30C Carbon Dioxide Detector/Transmitter Models Guide
G01-CO2-N X 0 C - Y 0 1 - U 02/05/50 - T/TH - Txx |
|
X: |
LCD or no LCD |
|
1- Without LCD, 24VAC/VDC power supply 3- LCD display, 24VAC/VDC power supply |
C: |
24VAC/VDC power supply |
Y: |
analog output quantity |
|
3- 3Xanalog outputs (for CO2, temperature, humidity) 2- 2Xanalog outputs (for CO2, temperature) 1- 1xanalog output (for CO2) 0- no analog output |
U: |
type of analog output |
|
V- 0~10VDC (default) A- 4~20mA V5- 0~5VDC (not be changed) |
02/05/50: |
CO2 range |
|
02- 0~2,000ppm 05- 0~5,000ppm 50- 0~50,000ppm |
T/TH: |
temperature option/ temperature and humidity option |
Txx: |
temperature scaling |
|
T05: 0°C~50°C(32°F~122°F) default (without the postfix indicates the default) T06: 0°C~60°C(32°F~140°F) T26: -20°C~60°C(-4°F~140°F) |
Accessory (selectable in the order)
921: wall mounting plate
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether