• CO2 detection with 0~2000ppm range
• 0~5000ppm/0~50000ppm range selectable
• CO2 Accuracy: ±30ppm + 3% of reading @22°C
• Temperature dependence: 0.2% FS per °C
• Stability: <2% of FS over life of sensor
• Power supply: 24VAC/VDC±10%
• Consumption: 2.2 W max. ; 1.6 W avg.
• Operation temperature: 0~50°C (32~122°F)
​• Operation humidity​: 0~95%RH, non condensing

  • Model Number: G01-CO2-N10C/30C
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

BACnet Carbon Dioxide (CO2) Detector/Transmitter
with Temperature and RH% Option
Model#: G01-CO2-N10C/30C


G01-CO2-N10C/30C Carbon Dioxide Detector/Transmitter Features
• BACnet communication
• CO2 detection with 0~2000ppm range
• 0~5000ppm/0~50000ppm range selectable
• NDIR infrared CO2 sensor with More than 10 years lifetime
• Patented self-calibration algorithm
• Optional temperature and humidity detection
• Provide up to 3xanalog linear outputs for measurements
• Optional LCD display of CO2 and temperature and humidity
• 24VAC/VDC power supply
• EU standard and CE-approval


G01-CO2-N10C/30C Carbon Dioxide Detector/Transmitter Specifications

CO2 Measurement
Sensing element
Non-Dispersive Infrared Detector (NDIR) 
CO2 range
0~2000ppm
0~5,000ppm/0~50,000ppm optional
CO2 Accuracy
±30ppm + 3% of reading @22°C(72°F)
Temperature dependence
0.2% FS per °C
Stability
<2% of FS over life of sensor (15 year typical)
Pressure dependence
0.13% of reading per mm Hg
Calibration
ABC Logic Self Calibration Algorithm
Response time
<2 minutes for 90% step change typical
Signal update 
Every 2 seconds 
Warm-up time
2 hours (first time) / 2 minutes (operation) 

Temperature
Humidity
Measuring range
0°C~50°C(32°F~122°F) (default)
0 -100%RH
Accuracy
±0.4°C (20°C~40°C)
±3%RH (20%-80%RH)
Display resolution 
0.1°C
0.1%RH
Stability 
<0.04°C/year
<0.5%RH/year
General Data
Power supply
24VAC/VDC±10%
Consumption
2.2 W max. ; 1.6 W avg.
Analog outputs
1~3 X analog outputs
0~10VDC(default) or 4~20mA (selectable by jumpers)
0~5VDC (selected at placing the order)
Operation conditions
0~50°C (32~122°F); 0~95%RH, non condensing
Storage conditions 
10~50°C (50~122°F)
20~60%RH
Net Weight
250g
Dimensions
130mm(H) x 85mm(W) x 36.5mm(D)
Installation
wall mounting with 65mm x 65mm or 2" x 4" wire box
Housing and IP class
PC/ABS fireproof plastic material, protection class: IP30
Standard
CE-Approval


G01-CO2-N10C/30C Carbon Dioxide Detector/Transmitter Models Guide

G01-CO2-N X 0 C - Y 0 1 - U 02/05/50 - T/TH - Txx
X:  
LCD or no LCD

1- Without LCD, 24VAC/VDC power supply
3- LCD display, 24VAC/VDC power supply
C:  
24VAC/VDC power supply
Y:  
analog output quantity

3- 3Xanalog outputs (for CO2, temperature, humidity)
2- 2Xanalog outputs (for CO2, temperature)
1- 1xanalog output (for CO2)
0- no analog output
U:  
type of analog output

V- 0~10VDC (default)
A- 4~20mA
V5- 0~5VDC (not be changed)
02/05/50:  
CO2 range

02- 0~2,000ppm
05- 0~5,000ppm
50- 0~50,000ppm
T/TH:  
temperature option/ temperature and humidity option
Txx:  
temperature scaling

T05: 0°C~50°C(32°F~122°F) default (without the postfix indicates the default)
T06: 0°C~60°C(32°F~140°F)
T26: -20°C~60°C(-4°F~140°F)

Accessory (selectable in the order)
921: wall mounting plate