• Supply Supply Voltage: +4.5 to +5.5 Vdc
• Common-mode pressure: -10 to +10 psig
• Lead Temperature, max (soldering 2-4 sec.): 250°C
• Compensated Temperature: -25 to 85 °C
• Operating Temperature: -40 to 125 °C
• Storage Temperature: -40 to 125 °C
• Humidity Limits: 0 to 95% RH (non condensing)

  • Model Number: 1 PSI-D-4V-PRIME
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Amplified Middle Pressure Sensors
Industrial Temperature Grade

AXCA Series Prime Grade Amplified Middle Pressure Sensors General Description
The Amplified line of middle pressure sensors is based upon a proprietary package technology to reduce errors. This model provides a ratiometric 4-volt output with superior output characteristics. The sensor housing has been designed specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.

These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor is internally compensated using an ASIC compensation technique. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

AXCA Series Prime Grade Amplified Middle Pressure Sensors Features
• 0 to 0.3 psi to 0 to 100 psi Pressure Ranges
• Ratiometric 4V Output
• Temperature Compensated (-25C to 85C)
• Calibrated Zero and Span

AXCA Series Prime Grade Amplified Middle Pressure Sensors Applications
• Medical Instrumentation
• Environmental Controls
• HVAC

AXCA Series Prime Grade Amplified Middle Pressure Sensors

Pressure Sensor Ratings

Environmental Specifications
Supply Supply Voltage VS
+4.5 to +5.5 Vdc
Compensated Temperature
-25 to 85 °C
Common-mode pressure
-10 to +10 psig
Operating Temperature
 -40 to 125 °C
Lead Temperature, max (soldering 2-4 sec.) 
250°C
Storage Temperature
-40 to 125 °C


Humidity Limits 
0 to 95% RH (non condensing)

AXCA Series Prime Grade Amplified Middle Pressure Sensors Standard Pressure Ranges
Part Number
Operating Pressure
Nominal Span
Proof Pressure
Burst Pressure
0.3 PSI-D-4V-PRIME
±0.3 PSI
4 V
5 PSI
10 PSI
0.3 PSI-G-4V-PRIME
0 - 0.3 PSI
4 V
5 PSI
10 PSI
1 PSI-D-4V-PRIME
±1 PSI
4 V
5 PSI
10 PSI
1 PSI-G-4V-PRIME
0 - 1 PSI
4 V
5 PSI
10 PSI
5 PSI-D-4V-PRIME
±5 PSI
4 V
15 PSI
30 PSI
5 PSI-G-4V-PRIME
0 - 5 PSI
4 V
15 PSI
30 PSI
15 PSI-A-4V-PRIME
0 - 15 PSIA
4 V
45 PSI
60 PSI
15 PSI-D-4V-PRIME
±15 PSI
4 V
45 PSI
60 PSI
15 PSI-G-4V-PRIME
0 - 15 PSI
4 V
45 PSI
60 PSI
30 PSI-A-4V-PRIME
0 - 30 PSIA
4 V
90 PSI
150 PSI
30 PSI-D-4V-PRIME
±30 PSI
4 V
90 PSI
150 PSI
30 PSI-G-4V-PRIME
0 - 30 PSI
4 V
90 PSI
150 PSI
100 PSI-A-4V-PRIME
0 - 100 PSIA
4 V
150 PSI
150 PSI
100 PSI-D-4V-PRIME
±100 PSI
4 V
150 PSI
150 PSI
100 PSI-G-4V-PRIME
0 - 100 PSI
4 V
150 PSI
150 PSI