AXCA Series Amplified Middle Pressure Sensors - 1 PSI-D-4V/1 PSI-G-4V
• Supply Voltage: +4.5 to +5.5 Vdc
• Common-mode pressure: -10 to +10 psig
• Lead Temperature, max (soldering 2-4 sec.): 250°C
• Compensated Temperature: 5 to 50 °C
• Operating Temperature: -25 to 85 °C
• Storage Temperature: -40 to 125 °C
• Humidity Limits: 0 to 95% RH (non condensing)
- Quantity:
- - +
Product Specification
AXCA Series Amplified Middle Pressure Sensors General Description
The Amplified line of middle pressure sensors is based upon a proprietary package technology to reduce errors. This model provides a ratiometric 4-volt output with superior output characteristics. The sensor housing has been designed specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor is internally compensated using an ASIC compensation technique. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.
AXCA Series Amplified Middle Pressure Sensors Features
• 0 to ±0.3 to 0 to 150 psi Pressure Ranges
• Ratiometric 4V Output
• Temperature Compensated
• Calibrated Zero and Span
AXCA Series Amplified Middle Pressure Sensors Applications
• Medical Instrumentation
• Environmental Instrumentation
• HVAC Instrumentation
AXCA Series Amplified Middle Pressure Sensors
Pressure Sensor Ratings |
|
Environmental Specifications |
||
Supply Voltage, Vs |
+4.5 to +5.5 Vdc |
Compensated Temperature |
5 to 50 °C |
|
Common-mode pressure |
-10 to +10 psig |
Operating Temperature |
-25 to 85 °C |
|
Lead Temperature, max (soldering 2-4 sec.) |
250°C |
Storage Temperature |
-40 to 125 °C |
|
|
|
Humidity Limits |
0 to 95% RH (non condensing) |
AXCA Series Amplified Middle Pressure Sensors Standard Pressure Ranges
Part Number |
Operating Pressure |
Nominal Span |
Proof Pressure |
Burst Pressure |
0.3 PSI-D-4V |
±0.3 PSI |
±2 V |
5 PSI |
10 PSI |
0.3 PSI-G-4V |
0 - 0.3 PSI |
4 V |
5 PSI |
10 PSI |
1 PSI-D-4V |
±1 PSI |
±2 V |
5 PSI |
10 PSI |
1 PSI-G-4V |
0 - 1 PSI |
4 V |
5 PSI |
10 PSI |
2.5 PSI-D-4V |
±2.5 PSI |
±2 V |
10 PSI |
20 PSI |
2.5 PSI-G-4V |
0 - 2.5 PSI |
4 V |
10 PSI |
20 PSI |
5 PSI-D-4V |
±5 PSI |
±2 V |
15 PSI |
30 PSI |
5 PSI-G-4V |
0 - 5 PSI |
4 V |
15 PSI |
30 PSI |
15 PSI-A-4V |
0 - 15 PSIA |
4 V |
45 PSI |
60 PSI |
15 PSI-D-4V |
±15 PSI |
±2 V |
45 PSI |
60 PSI |
15 PSI-G-4V |
0 - 15 PSI |
4 V |
45 PSI |
60 PSI |
30 PSI-A-4V |
0 - 30 PSIA |
4 V |
60 PSI |
60 PSI |
30 PSI-D-4V |
±30 PSI |
±2 V |
60 PSI |
60 PSI |
30 PSI-G-4V |
0 - 30 PSI |
4 V |
60 PSI |
100 PSI |
100 PSI-A-4V |
0 - 100 PSIA |
4 V |
150 PSI |
150 PSI |
100 PSI-D-4V |
±100 PSI |
±2 V |
150 PSI |
150 PSI |
100 PSI-G-4V |
0 - 100 PSI |
4 V |
150 PSI |
150 PSI |
150 PSI-D-4V |
±150 PSI |
±2 V |
200 PSI |
200 PSI |
150 PSI-G-4V |
0 - 150 PSI |
4 V |
200 PSI |
200 PSI |
BARO-A-4V |
600 - 1100 mbarA |
4 V |
45 PSI |
60 PSI |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃