ADCA Series Amplified Low Pressure Sensors - 5 INCH-D-4V-PRIME

  • ADCA Series Amplified Low Pressure Sensors
  • ADCA Series Amplified Low Pressure Sensors
Mouse over image to zoom

• 0.25 to 60 inH2O Pressure Ranges
• Supply Voltage: +4.5 to +5.5 Vdc
• Common-mode pressure: -10 to +10 psig
• Lead Temperature, max (soldering 2-4 sec.): 270°C
• Operating & Storage Temperature: -40 to 125 °C
• Humidity Limits: 0 to 95% RH (non condensing)
• Calibrated Zero and Span

  • Model Number: 5 INCH-D-4V-PRIME
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

ADCA Series Amplified Low Pressure Sensors General Description
The ADCA series of Amplified low pressure sensors are based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration en­hanced structure to provide a very linear output to measured pressure. 

These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. 

The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.

ADCA Series Amplified Low Pressure Sensors Features
• 0.25 to 60 inH2O Pressure Ranges
• Ratiometric 4V Amplified Output
• Temperature Compensated Ranges Available in Standard, Industrial and Military ranges.
• Calibrated Zero and Span

ADCA Series Amplified Low Pressure Sensors Applications
• Medical Instrumentation
• Environmental Controls
• HVAC

ADCA Series Amplified Low Pressure Sensors 

Pressure Sensor Ratings

Environmental Specifications
Supply Voltage VS
+4.5 to +5.5 Vdc
Compensated Temperature

Common-mode pressure 
-10 to +10 psig
    Standard:
5 °C to 50 °C
Lead Temperature, max 
(soldering 2-4 sec.)

270°C
    Industrial:
-25 °C to 85 °C


    Military:
-40 °C to 125 °


Operating & Storage Temperature
-40 to 125 °C


Humidity Limits 
0 to 95% RH (non condensing)

ADCA Series Amplified Low Pressure Sensors Standard Pressure Ranges
Device
Operating Range
Pressure Type
Nominal Span
Proof Pressure
Burst Pressure
Specification
Notes
inH2O
Pa
inH2O
kPa
inH2O
kPa
0.25 INCH-D-4V
±0.25
65
Differential
4V
40
10
80
20
1
0.25 INCH-G-4V
0 to 0.25
65
Gage
4V
40
10
80
20
1
0.5 INCH-D-4V
±0.5
125
Differential
4V
40
10
80
20
1
0.5 INCH-G-4V
0 to 0.5
125
Gage
4V
40
10
80
20
1
1 MBAR-D-4V
±1 mbar
100
Differential
4V
100
25
200
50
1
1 INCH-D-4V
±1
250 Differential
4V
100
25
200
50
-
1 INCH-G-4V
0 to 1
250
Gage
4V
100
25
200
50
-
2.5 INCH-D-4V
±2.5
625
Differential
4V
200
50
300
75
1
2.5 INCH-G-4V
0 to 2.5
625
Gage
4V
200
50
300
75
-
5 INCH-D-4V
±5
1,250
Differential
4V
200
50
300
75
-
5 INCH-G-4V
0 to 5
1,250
Gage
4V
200
50
300
75
-
10 INCH-D-4V
±10
2,500
Differential
4V
200
50
300
75
-
10 INCH-G-4V
0 to 10
2,500
Gage
4V
200
50
300
75
-
20 INCH-D-4V
±20
5,000
Differential
4V
300
75
500
125
-
20 INCH-G-4V
0 to 20
5,000
Gage
4V
300
75
500
125
-
30 INCH-D-4V
±30
7,500
Differential
4V
500
125
800
200
-
30 INCH-G-4V
0 to 30
7,500
Gage
4V
500
125
800
200
-
40 INCH-G-4V
0 to 40
10,000
Gage
4V
500
125
800
200
1
60 INCH-G-4V
0 to 60
15,000
Gage
4V
500
125
800
200
1

ADCA Series Amplified Low Pressure Sensors Ordering Information:

Where:
Compensation Temperature Range: ___________ (empty – indicates Standard)
Compensation Temperature Range: "—PRIME" indicates Industrial
Compensation Temperature Range: "—MIL" indicates Military
Example: 5 INCH-D-4V-PRIME

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service