Distribution mechanical strength: ≥30N/ Arbitrary direction
Flow characteristics: F=(7.5*Q) error≤2%
High level: ≥4.6V
Low level: ≤0.5V
Electrical strength: 1250V/min
Insulation resistance: ≥100MΩ
Water pressure test: ≤1.75Mpa
- Quantity:
- - +
Product Specification
YF-S201 Water Flow Sensor Description
The external dimensions and indicated contents are consistent with the approved drawings and technical documents approved by the procedures. The installation is well coordinated and has a permanent flow direction sign.There are no obvious cracks, bumps, burrs and deformations on the surface.The water flow sensor is connected with the 5V power supply, and is directly measured by the oscilloscope through the 8L/min water flow. The water flow sensor can be artificially placed at the high level and tested with a multimeter voltage profile.Mainly used in water heaters, drinking fountains, water vending machines, campus credit card machines and other fields.
YF-S201 Water Flow Sensor Specification
Product appearance |
Conform to the design |
The external dimensions and indicated contents are consistent |
There are no obvious cracks, bumps, burrs and deformations on the surface. |
||
Distribution mechanical |
≥30N/ Arbitrary direction |
Pull the wiring with a tension gauge,give the force1min/30N |
Flow characteristics |
F=(7.5*Q) error≤2% |
2 to 12L/min water flow is applied at the inlet of the water flow sensor, and its output frequency characteristics should meet the standard requirements, formula F is Hz, Q is L/min. |
High level |
≥4.6V |
The water flow sensor is connected with the 5V power supply, |
Low level |
≤0.5V |
|
Electrical strength |
1250V/min |
In the case with any lead wire, the experimental voltage is 1250V, the setting current is 8mA, the experimental time is 1min, no breakdown, no flashover. |
Insulation resistance |
≥100MΩ |
In 500V/ measuring insulation resistance. |
Output duty cycle |
50%± 10% |
The flow sensor is connected to the 5V power source and is |
low temperature |
Flow characteristics, |
1) place the sample in -20℃ constant temperature box 2h, |
high temperature |
||
thermal shock |
||
damp |
The sample at the temperature of 40± 2℃, the relative humidity |
|
Water pressure test |
≤1.75Mpa |
Stop the water flow sensor plug, applied pressure is less than or equal to 1.75MPa at the other end, the flow sensor without any leakage. |