Ultra High Resolution Digital Measurement Pressure Transducer - TD2000 Series

  • Ultra High Resolution Digital Measurement Pressure Transducer
  • Ultra High Resolution Digital Measurement Pressure Transducer
Mouse over image to zoom

• Totally digital proprietary design
• Innovative redundent sensing elements
• 24V digital output for pressure or temp switch point
• Variety of voltage outputs available
• Custom pressure Ranges and outputs available
• More standard pressure ranges, Industry First
• 2x overpressure rating
• 0.05% BFSL accuracy
• ASIC technology, no zero/span potentiometers

  • Model Number: TD2000 Series
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

The TD2000 Series Ultra High Resolution Digital Measurement, General Purpose, Pressure Transducer

TD2000 Series Pressure Transducer FEATURES
• Totally digital proprietary design
• Innovative redundent sensing elements
• 24V digital output for pressure or temp switch point
• Variety of voltage outputs available
• Custom pressure Ranges and outputs available
• More standard pressure ranges, Industry First
• 2x overpressure rating
• 0.05% BFSL accuracy
• ASIC technology, no zero/span potentiometers
• All stainless steel welded housing
• IP-69K rated seal available (high pressure wash down)
• Innovative low current consumption, ideal for custom wireless solutions
• Calibration Certifi cates provided

TD2000 Series Pressure Transducer DESCRIPTION
The TD2000 Series digital/confi gurable (an industry fi rst) industrial pressure transducer features excellent stability and precision accuracy over a wide temperature range at lower cost than competitive units.

With its proprietary digital/ASIC technology, the TD2000 Series features fi eld proven redundant sensing elements without the need for solder in resistors or trim pots that can drift over time. This provides years of excellent performance and reliability even in the harshest/demanding applications. This combined with the optional integrated temperature or pressure digital switch feature, makes the TD2000 Series truly an industry fi rst and second to none.

For extreme applications where power washers are used for wash down, the TD2000 Series optional IP69K seal, another industry fi rst, makes it ideal no matter what the environment.

With its fl exible low power design and lower manufacturing costs, the TD2000 Series offers outstanding value and makes it ideal for custom wireless applications.

TD2000 Series Pressure Transducer SPECIFICATIONS

Performance

 Performance @ 25°C (77°F)

Accuracy

 0.05% BFSL

Overange Protection

 2x Rated Pressure

Pressure Range

 see ordering chart - up to 6000 psi (414 bar) (optional higher ranges available)

Burst Pressure

 5x or 20,000 psi, whichever is less

Pressure Cycles

 >100 million

Update Time

 <=1msec

Digital Output

 Optional digital output for pressure, maintenance or temp switch point, max load current 20mA

Environmental Data

Temperature

 

Compensated Temperatures

 24 to 60°C (75 to 140°F)

Operating Temperatures

 -40 to 100°C (-40 to 212°F)

Storage

 -40 to 125°C (-40 to 250 F)

TEB

 0.25% BFSL (includes:Non-linearity, Hysteresis and Non-repeatability)

Long Term Drift

 0.2% FS/year (non-cumulative)

Shock

 100g, 11 ms, 1/2 sine

Vibration

 20g, peak, 20 to 2400 Hz

EMI/FRI Protection

 Yes

Rating

 Up to IP-69K available (high pressure wash down)

Approvals

 CE

Mechanical Configuration

Pressure Connections

 See ordering chart

Wetted Material

 17-4PH stainless steel (for other materials consult factory)

Electrical Connection

 Cable, 9.4 Din, IP-69K 4 pin M12 Connector

Case

 (housing) 304 stainless steel

Electrical Data

Excitation

 3.5-28VDC, Typ (must be at least 0.3V above full output voltage)

Output

 see ordering chart

Output Impedance

 <100 Ohms, Nominal

Current Consumption

 <5mA (voltage output)

Output Noise

 <2mV RMS

Reverse Polarity Protection

 Yes

Zero and Span Offset Tolerance

 1%

Set Point % for Pressure or Temp

 For pressure, this is done by selecting a percentage of your transducer’s full range and

 this will be the set point (40% of a 1000 psi range will have the set point at 400psi)“P40”.

 For temperature, select what percentage of 80°C you want the set point to be (70% of

 80°C is 56°C [132.8°F] and this will be the set point)“T70”.

Maintenance Mode

 The maintenance mode output indicates 1/2 bridge failure


TD2000 Series Pressure Transducer ORDERING


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service