Transmitter (Current Amplifier) of Photocurrent to 4 - 20mA Current Loop - AMPCON Series
• transmitter (current amplifier) with output current 4 to 20 mA
• to include photodiodes into an industrial 4 to 20 mA data bus
• maximum photocurrent: 250 µA, 2.5 µA or 25 nA
- Quantity:
- - +
Product Specification
AMPCON series
Transmitter of photocurrent to 4 - 20 mA current loop
AMPCON Series Transmitter (current Amplifier) of Photocurrent Properties
The AMPCON converts a photocurrent to an industry standard current loop signal. It exhibits a loop-powered (passive) 4 to 20 mA sensor to any PLC system.
Three models with different measurement ranges are available. Gain and offset can be adjusted by potentiometers. The measurement range can also be customized by replacing passive components.
AMPCON Series Transmitter (current Amplifier) of Photocurrent Specifications
We strongly recommend to process this product on ESD protected workplaces.
Parameter
Value
Photocurrent measurement range
AMPCON_low 250 µA
AMPCON_med 2.5 µA
AMPCON_high 25 nA
Loop supply voltage
(10 to 24) V ± 10 % depending on loop resistance
Total loop resistance
<= 700 Ω@ 24V, <= 100 Ω at 10V
Gain adjustment range
± 35%
Offset adjustment range
4 mA (±12.5%)
Dimensions
13 x 26 x 8 mm (WxLxH)
Operating temperature
-20 to +80 °C
Storage temperature
-40 to +80 °C
Standards
RoHS 2 2011/65/EU, DIN IEC 60381-1
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing Service