Tin Dioxide Semiconductor Gas Sensor for Refrigerant Detection(HFCs) - SP-42A-00
• Target gas: HFCs (R134a,R-410a,R-407c)
• Heater voltage: 5.0 V ± 4%
• Circuit voltage: 5.0 V ± 4%
• Operating temperature: -10°C to 60°C
• Storage temperature: -20°C to 70°C
• Relative humidity: Less than 95% RH
• Sensor resistance: 04kΩ to 40kΩ
• Industrial gas leak detector
- Quantity:
- - +
Product Specification
SP-42A-00 Gas Sensor for Refrigerant Detection Description
The SP-42A is a tin dioxide semiconductor gas sensor which has a high sensitivity to HFCs (e.g. Freon: R-134a) with improved cross sensitivity to other gases.
This model is suitable for R-134a, R-410a, R- 407c and other new Freon family which contain R-134a.
SP-42A-00 Gas Sensor for Refrigerant Detection Application
• Industrial gas leak detector
SP-42A-00 Gas Sensor for Refrigerant Detection Specifications
Standard Operating conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
VH |
Heater voltage |
5.0 V ± 4 % |
AC or DC |
VC |
Circuit voltage |
5.0 V ± 4 % |
AC or DC |
RL |
Load resistance |
Variable |
PS < 15 mW |
RH |
Heater resistance |
40 Ω ± 2 Ω |
at room temperature |
PH |
Heater power consumption |
400 mW (Typical value) |
PH = VH2 / RH |
PS |
Power dissipation of sensing element |
Less than 15 mW |
PS =(VC - VRL)2/RS |
Environmental conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
Tao |
Operating temperature |
-10°C to 60°C |
Recommended range |
Tas |
Storage temperature |
-20°C to 70°C |
|
RH |
Relative humidity |
Less than 95% RH |
|
(O2) |
Oxygen concentration |
21% ± 1% (Standard condition) |
Absolute minimum level: more than 18% |
The sensitivity characteristics are influenced by the variation in oxygen concentration. |
|||
Sensitivity characteristics |
|||
Model |
SP-42A-00 |
||
Symbol |
Parameter |
Specification |
Conditions etc. |
RS |
Sensor resistance |
4kΩ to 40kΩ |
At 100 ppm of R-134a |
β |
Ratio of sensor resistance |
0.50 to 0.65 |
Rs at 300 ppm of 134a Rs at 100 ppm of R-134a |
R/Rair |
Resistance change in gas/air |
≤ 0.40 |
Rs at 100 ppm of 134a
Rs in air
|
Standard Test Conditions: |
Temp: 20°C ± 2°C Humidity:65% ± 5% (in clean air) |
VC : 10.0 V ± 1%
VH : 5.0 V ± 1%
RL : 10 kΩ ± 5%
|
|
Pre-heating time: more than 48 hours |
|||
Mechanical characteristics |
|||
Items |
Conditions |
Specifications |
|
Vibration |
Frequency: Vertical amplitude: Duration: |
100 cpm 4 mm 1 hour |
Should satisfy the specifications shown in the sensitivity characteristics. |
Shock |
Acceleration: Number of impacts: |
100 G 5 times |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Long life electrochemical oxygen sensor (O2 sensor )
-
Air quality sensor VOC sensor
-
VOC Air quality sensor Formaldehyde sensor
-
Combustible gas sensor Natural Gas sensor TGS2611
-
Flammable gas sensor Liquefied petroleum gas sensor TGS2610
-
Methane and LP Gas sensor
-
Methane and LP Gas sensor
-
Alcohol sensor
-
Combustible Gases sensor
-
Hydrogen Gas Sensor