Tin Dioxide Semiconductor Gas Sensor for Hydrocarbon Detection - SB-11A-00
• Target gas: Methane/Propane/Hydrocarbons/Hydrogen
• Heater voltage: 0.9 V ± 0.05 V
• Circuit voltage: Less than 5 V
• Operating temperature: -20°C to 50°C
• Storage temperature: -20°C to 70°C
• Relative humidity: Less than 95% RH
• Sensor resistance: 0.2kΩ to 1.0 kΩ
• Home gas leak detector
- Quantity:
- - +
Product Specification
SB-11A-00 Hydrocarbon Gas Sensor Description
The SB-11A is a tin dioxide semiconductor gas sensor which has an excellent performance in methane, propane, butane and other hydrocarbons detection with significant low power consumption concept (120mW).
High sensitivity, low sensitivity to noise gases, quick response speed and strong poisoning resistance features achieve reliable gas detection system applications.
SB-11A-00 Hydrocarbon Gas Sensor Application
• Home gas leak detector
SB-11A-00 Hydrocarbon Gas Sensor Specifications
Standard Operating conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
VH |
Heater voltage |
0.9 V ± 0.05 V |
AC or DC |
VC |
Circuit voltage |
Less than 5 V |
DC (polarity is important) |
RL |
Load resistance |
Variable (> 200 Ω) |
PS < 10 mW |
RH |
Heater resistance |
2.8 Ω ± 0.2 Ω |
at room temperature |
IH |
Heater current |
130 mA |
IH = VH / RH (typical value) |
PH |
Heater power consumption |
120 mW |
PH = VH2 / RH (typical value) |
PS |
Power dissipation of sensing element |
Less than 10 mW |
PS = (VC - VRL)2/RS |
Environmental conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
Tao |
Operating temperature |
-20°C to 50°C |
Recommended range |
Tas |
Storage temperature |
-20°C to 70°C |
|
RH |
Relative humidity |
Less than 95% RH |
|
(O2) |
Oxygen concentration |
21% (Standard condition) |
Absolute minimum level: more than 18% |
The sensitivity characteristics are influenced by the variation in oxygen concentration. |
|||
Sensitivity characteristics |
|||
Model |
SB-11A-00 (revised on March 6, 2008) |
||
Symbol |
Parameter |
Specification |
Conditions etc. |
RS |
Sensor resistance |
0.2kΩ to 1.0 kΩ |
at methane 3000 ppm |
β |
Sensitivity |
0.48 to 0.68 |
Rs (at CH4 3000 ppm)
Rs (at CH4 1000 ppm) |
γ |
Sensitivity |
≥ 8.0 |
Rs (in air)
Rs (at i-C4H10 1000 ppm) |
∆ |
Sensitivity |
≥ 10.0 |
Rs (in air)
Rs (at CH4 3000 ppm) |
Standard Test Conditions: |
Temp: 20°C ± 2°C Humidity:65% ± 5% (in clean air) |
VC : 5.0 V ± 1% VH : 0.9 V ± 1% RL : 750 Ω ± 5% |
|
Pre-heating time: more than 48 hours |
|||
Mechanical characteristics |
|||
Items |
Conditions |
Specifications |
|
Vibration |
Frequency: Vertical amplitude: Duration: |
100 cpm 4 mm 1 hour |
Should satisfy the specifications shown in the sensitivity characteristics. |
Shock |
Acceleration: Number of impacts: |
100 G 5 times |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Long life electrochemical oxygen sensor (O2 sensor )
-
Air quality sensor VOC sensor
-
VOC Air quality sensor Formaldehyde sensor
-
Combustible gas sensor Natural Gas sensor TGS2611
-
Flammable gas sensor Liquefied petroleum gas sensor TGS2610
-
Methane and LP Gas sensor
-
Methane and LP Gas sensor
-
Alcohol sensor
-
Combustible Gases sensor
-