• Target gas: Carbon Monoxide/Methane
• Heater voltage (high): 0.9 V ± 5%
• Heater voltage (low): 0.2 V ± 5%
• Circuit voltage: Less than 5 V
• Operating temperature: -10°C to 60°C
• Storage temperature: -30°C to 100°C
• Relative humidity: Less than 95% RH
- Quantity:
- - +
Product Specification
SB-95-12 Carbon Monoxide and Methane Sensor Description
The SB-95-12 is a tin dioxide semiconductor gas sensor which has an excellent performance in detecting both CO and methane selectively with single sensor element. This unique feature was realized by using a mini-bead type sensing element with a periodic temperature change operation method.
SB-95-12 Carbon Monoxide and Methane Sensor Application
• Home gas leak detector
SB-95-12 Carbon Monoxide and Methane Sensor Specifications
Standard Operating conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
VH (H) |
Heater voltage (high) |
0.9 V ± 5% |
AC, DC or pulse |
VH (L) |
Heater voltage (low) |
0.2 V ± 5% |
AC, DC or pulse |
VC |
Circuit voltage |
Less than 5 V |
DC: Pin2 (+) - Pin 1 (-) |
RL |
Load resistance |
Variable (> 200 Ω) |
PS < 10 mW |
RH |
Heater resistance |
2.8 Ω ± 0.2 Ω |
at room temperature |
TH (H) |
Heating time (high) |
5 sec ± 0.1 sec |
|
TH (L) |
Heating time (low) |
20 sec ± 0.1 sec |
|
IS (H) |
Current consumption (high) |
132mA ± 15mA |
VH=0.9V |
IS (L) |
Current consumption (low) |
59mA ± 10mA |
VH=0.2V |
PS |
Power dissipation
|
Less than 10 mW |
|
Environmental conditions |
|||
Symbol |
Parameter |
Specification |
Conditions etc. |
Tao |
Operating temperature |
-10°C to 60°C |
Recommended range |
Tas |
Storage temperature |
-30°C to 100°C |
|
RH |
Relative humidity |
Less than 95% RH |
|
(O2) |
Oxygen concentration |
21% ± 1% (Standard condition) |
Absolute minimum level: more than 18% |
The sensitivity characteristics are influenced by the variation in oxygen concentration. Please consult FIS for details. |
|||
Sensitivity characteristics |
|||
Model |
SB-30-00 |
||
Symbol |
Parameter |
Specification |
Conditions etc. |
RS(L) |
Sensor resistance at LOW period |
4.5 kΩ - 40 kΩ |
at 100ppm of CO |
α(L)(30-100) |
Sensitivity slope (30 - 100 ppm) |
0.35 to 0.65 |
log (RS(30 ppm) / RS(100 ppm)) log (30/100) |
α(L)(100-300) |
Sensitivity slope at LOW period |
0.5 to 1.0 |
log (RS(300 ppm) / RS(100 ppm))
log (300/100)
|
RS(H) |
Sensitivity resistance at HIGH period |
0.2 kΩ - 2.3 kΩ |
at 3000ppm of methane |
β(H) |
Sensitivity slope at HIGH period |
0.45 to 0.65 |
RS(3000 ppm) / RS(1000 ppm) |
Standard Test Conditions: |
Temp: 20°C ± 2°C Humidity: 65% ± 5% (in clean air) |
VC : 5.0 V ± 5%
VH (high) : 0.9 V ± 5% VH (low) : 0.2 V ± 5% RL (high) : 750Ω ± 1% RL (low) : 10 kΩ ± 1% |
|
Pre-heating time: more than 4 days |
|||
Mechanical characteristics |
|||
Items |
Conditions |
Specifications |
|
Vibration |
Frequency: Acceleration: Sweep time: |
5 - 500 Hz 1.3G 40 min. |
Should satisfy the specifications shown in the sensitivity characteristics after test. |
Drop |
Height: Number of impacts: |
60 cm 3 times |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Long life electrochemical oxygen sensor (O2 sensor )
-
Air quality sensor VOC sensor
-
VOC Air quality sensor Formaldehyde sensor
-
Combustible gas sensor Natural Gas sensor TGS2611
-
Flammable gas sensor Liquefied petroleum gas sensor TGS2610
-
Methane and LP Gas sensor
-
Methane and LP Gas sensor
-
Alcohol sensor
-
Combustible Gases sensor
-
Hydrogen Gas Sensor