Sulfur Dioxide Sensor (SO2 Sensor) - SO2-AF

  • Sulfur Dioxide Sensor (SO2 Sensor)
  • Sulfur Dioxide Sensor (SO2 Sensor)
Mouse over image to zoom

• Range: 50ppm limit of performance warranty
• Sensitivity: 300 to 550​ nA/ppm in 10ppm SO2
• Response time t90: < 35 (s) from zero to 10ppm SO2
• Resolution: < 0.1 RMS noise (ppm equivalent)
• Operating life: > 24 months
• Temperature range: -30 to 50​ °C​
• Pressure range​: 80 to 120​ kPa
• Humidity range​: 15 to 90 % rh continuous​
• Weight: < 6g

  • Model Number: SO2-AF
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

SO2-AF Sulfur Dioxide Sensor SO2 Sensor Description
Alphasense Sulfur Dioxide gas sensors operate using proven fuel cell technology.

SO2-AF  Sulfur Dioxide Sensor size:
20mm diameter, the industry standard size for portable gas detectors

The SO2 range provides OEMs with reliable sensors for use in a variety of applications. Strong signal levels combined with low zero current allows resolution below 1ppm and an operating range for safety applications up to 2,000ppm. The sensors are designed for use in both fixed site and portable instrumentation.

The SO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.


SO2-AF Sulfur Dioxide Sensor SO2 Sensor Schematic Diagram


SO2-AF Sulfur Dioxide Sensor SO2 Sensor PERFORMANCE
Sensitivity
nA/ppm in 10ppm SO2
300 to 550
Response time
t90 (s) from zero to 10ppm SO2
< 35
Zero current
ppm equivalent in zero air
< ± 0.6
Resolution
RMS noise (ppm equivalent)
< 0.1
Range
ppm limit of performance warranty
50
Linearity
ppm error at full scale, linear at zero and 10ppm
< ± 0.3
Overgas limit
maximum ppm for stable response to gas pulse
75



SO2-AF Sulfur Dioxide Sensor SO2 Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
<0.1
Sensitivity drift
% change/year in lab air, monthly test
< 4
Operating life
months until 80% original signal (24 month warranted)
> 24



SO2-AF Sulfur Dioxide Sensor SO2 Sensor ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 10ppm
70 to 90
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 10ppm
90 to 102
Zero @ -20°C
ppm equivalent change from 20°C
< ± 0.8
Zero @ 50°C
ppm equivalent change from 20°C
< ± 3



SO2-AF Sulfur Dioxide Sensor SO2 Sensor CROSS SENSITIVITY
Filter capacity
ppm·hrs H2S
1000
H2S sensitivity
% measured gas @ 20ppm H2S
< 3
NO2 sensitivity
% measured gas @ 10ppm NO2
< -130
Cl2 sensitivity
% measured gas @ 10ppm Cl2
< -60
NO sensitivity
% measured gas @ 50ppm NO
< ± 2
CO sensitivity
% measured gas @ 400ppm CO
< 1.6
H2 sensitivity
% measured gas @ 400ppm H2
< 0.3
C2H4 sensitivity
% measured gas @ 400ppm C2H4
< 40
NH3 sensitivity
% measured gas @ 20ppm NH3
< 0.1 



SO2-AF Sulfur Dioxide Sensor SO2 Sensor KEY SPECIFICATIONS
Temperature range
°C
-30 to 50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in sealed pot)
6
Load Resistor
Ω (recommended)
10 to 47
Weight
g
< 6

Matched Transmitter board for SO2-AF SO2 Sensor

4-20mA Digital Transmitter Board
   • Factory calibration, custom-set for immediate use
   • Digital zero, sensitivity and temperature compensation
   • Digital and 4-20mA output
   • Biased or unbiased operation
   • Calibration and range change

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service