STs Series ORP (redox) Sensor - 2001 ORP
• Replaceable electrode with platinum sensing element measuring -1000 to +1000 mV oxidationreduction potential (ORP)
• Large reference half-cell to reduce calibration frequency
• Secondary 0-50°C temperature sensor
• 2-wire, 4-20 mA analog outputs compatible with wide range of dataloggers or remote telemetry units (RTU)
• Narrow diameter (0.75 inches or 1.9 cm) for insertion down pipes or boreholes
• Low power usage
- Quantity:
- - +
Product Specification
Description:
The pHionics STs Series™ ORP is a low maintenance, dual-output sensor that pairs with a datalogger or RTU for real-time water quality monitoring. A narrow diameter allows the STs Series to go where other sensors cannot while a durable, chemical-resistant housing ensures many years in-use.
All parts, including the cable, are easily replaceable without tools using pHionics patented pHiConn™ System, saving frustration and money.
Highlighted Features:
• Replaceable electrode with platinum sensing element measuring -1000 to +1000 mV oxidationreduction potential (ORP)
• Large reference half-cell to reduce calibration frequency
• Secondary 0-50°C temperature sensor
• 2-wire, 4-20 mA analog outputs compatible with wide range of dataloggers or remote telemetry units (RTU)
• Narrow diameter (0.75 inches or 1.9 cm) for insertion down pipes or boreholes
• Low power usage
Applications:
• Groundwater Monitoring
o Agricultural Runoff
o Mining Pollution
• Industrial Effluent Monitoring
• Wastewater Treatment
• Environmental Remediation
• Aquaculture
Specifications:
ORP Sensor |
|
Output |
4-20 mA |
ORP (redox) Range |
-1000 to +1000 mV |
Operating Temperature |
0-70℃ |
Pressure Range |
0-70 psi |
Electrode Type |
Platinum sensing element,silver/silver chloride gel-filled reference |
Transmitter Type |
2-wire |
Automatic Temperature Compensation |
None |
Isolation |
600 VDC |
Power Supply Voltage |
8-40 VDC |
Warm-up Time |
2 seconds |
Response time |
95% < 20 seconds |
Wetted Materials |
316 Stainless Steel, Delrin®, Viton™, glass, epoxy |
Length |
14.25 in (36.20 cm) |
Width |
0.750 in (1.9 cm) maximum |
Weight (No cable) |
0.50 lbs (0.227 kg) |
Linearity |
± 4 mV |
Accuracy |
± 4 mV* |
Sensitivity |
± 2 mV |
Repeatability |
± 10 mV |
Temperature Sensor |
|
Output |
4-20 mA |
Temperature Range |
0-50℃ |
Accuracy |
+/- 1℃ |
Linearity |
+/- 0.5℃ |
Power Supply Voltage |
7-40 VDC |
Cable |
|
Cable Material |
Polyurethane |
Type |
4 conductor, Kevlar® reinforced, water blocked, shielded, twisted-pair wiring |
Maximum Distance |
3 miles |
Resistance per 1000 ft (304.8 m) |
26 Ohms |
Replaceable? |
Yes |
*After proper calibration
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Modular Flat Surface pH & ORP Electrodes
-
Industrial Contacting Conductivity Sensors
-
Toroidal Conductivity Sensor
-
Sanitary Flange Mounted Conductivity/Resistivity Sensor
-
Low Cost Epoxy Body Conductivity Sensors
-
Submersible Flat-Surface, Self-Cleaning pH and ORP Electrodes
-
Side-Stream/By-Pass Flat-Surface, Self-Cleaning pH and ORP Electrodes
-
Ground-Loop Interrupt Flat-Surface Self-Cleaning pH and ORP Electrodes
-
Low Cost Submersion and In-Line pH Electrodes
-
Insertion/Wet-tap Flat-Surface, Self-Cleaning pH and ORP Electrodes