Semiconductor gas sensor detects LP propane with Figaro TGS 2619 - AG-2-CH4-M2619(D)

  • Semiconductor gas sensor detects LP propane with Figaro TGS 2619
  • Semiconductor gas sensor detects LP propane with Figaro TGS 2619
Mouse over image to zoom

High selectivity to methane
Long life and low cost
Alarm output
USART digital output
pre-calibrated before leaving the factory

  • Model Number: AG-2-CH4-M2619(D)
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Semiconductor gas sensor detects LP propane with Figaro TGS 2619 AG-2-CH4-M2619(D) Product Description:
The AG-2-CH4-M2619(D) is an embedded type module equipped with the Figaro’s semiconductor Sensor TGS2619; the module has been pre-calibrated before leaving the factory and it includes a specialized filter that reduces interference from gases like alcohol, ensuring a selective response to methane (CH4). It utilizes digital communication through a USART and a programmable Alarm output interface for gas concentration readings. This allows users to easily and quickly integrate the module into residential gas leakage alarm systems, such as household natural gas detectors.



Features:
High selectivity to methane
Long life and low cost
Alarm output
USART digital output
pre-calibrated before leaving the factory



Technical Specification:



Item

Specification

Model Number

AG-2-CHX-M2619(D)

Target Gases

CH4

Sensing Principle

Semiconductor

Detection Range

0 ~ 20% LEL

Measurement Error

< ±3% LEL

Operating Voltage

5V±0.2V DC

Output Signal

USART

Alarm Point

10% LEL

Temperature Range

-40- 70°C

Humidity Range

20% ~ 95%RH

Pressure Range

1 ± 0.1 atm

Storage Temperature

-10 - 80°C

Size

L*W=31.1mm*30.3mm



If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service