• Temperature ranges: -40 to 1000 °C
• Spectral range: 8 to 14 µm
• Measurement accuracy: 0.6 % of measured value in °C or 1 K
• Reproducibility: 0.3 % of measured value in °C or 0.5 K
• Output: 0/4 to 20 mA, temperature linear, max. burden: 700 Ω
• Power supply: 24 V DC ± 25 %, residual ripple 500 mV
• Power consumption: max. 1.5 W
• Operating temperature: 0 °C to 70 °C (32 °F to 158 °F)
- Quantity:
- - +
Product Specification
PSC-T54L
Self-Contained 1-Color Pyrometer for General Purpose Applications
Digital pyrometer with 4-20mA output and RS-485 Modbus RTU Protocol
PSC-T54L Non-Contact Infrared Pyrometers Description
The digital model PSC-T54L series pyrometers are specifically designed for general purpose applications. They are suitable for temperature measurement between -40 to 1000°C on non-metallic or coated metallic surfaces.
The compact, rugged stainless steel housing with companion cooling jacket facilitates operation under even the most difficult ambient conditions. The PSC-T54L can measure small spot sizes starting from 0.028" (0.7 mm).
With a quick response time of 10 ms (adjustable) the PSC-T54L can pick up the tiniest changes in temperature faster than other devices, i.e., thermocouples.
The IR sensor provides dual lasers to determine focus distance and is used to aim and pinpoint the target under measurement. The laser can be activated remotely via RS-485 communication interface.
The standard 0/4 to 20 mA linear temperature output signal allows for easy implementation into existing measurement and control systems.
The PSC-T54L possesses a galvanically isolated RS-485 interface. As such, the devices are bus-compatible and use the Modbus RTUprotocol.
The pyrometer can be connected to a computer via an optional RS-485 to USB interface adapter. By connecting the IR sensor with a PC using PSCSpot software, parameters such as emissivity, sub-temperature range, data storage settings, and response time can be adjusted.
The IR sensor parameters can also be adjusted via RS-485 interface or through the optional available handheld programming device DHP 1040.
PSC-T54L Non-Contact Infrared Pyrometers Typical Industry Applications:
• Paper & Packaging
• Powders & Bulk solids
• Ceramics
• Wallboard
• Food
• Thermoforming Glass & Composites
PSC-T54L Infrared Temperature Sensor Special features
• Temperature ranges between -40°C and 1000°C
• Small spot sizes with high resolution optics-FOV 100:1
• 0/4 to 20 mA linear output, switchable
• Dual lasers for aiming
• Fast response time (10 ms)
• Integrated RS-485 interface and Modbus RTU
PSC-T54L Non-Contact Infrared Pyrometers Technical data
Model |
PSC-T54L |
|||
Temperature ranges |
0 °C to 1000 °C / 32°F to 1832°F |
-40 °C to 1000 °C / -40°F to 21832°F |
||
Fixed optics |
75 |
200 | 600 | 1500 |
Part number |
PSC-4548261202 |
PSC-4548262201 |
PSC-4548263201 |
PSC-4548264201 |
Sub temperature range |
adjustable via RS-485 interface within temperature range, minimum span 50 °C |
|||
Spectral range |
8 to 14 µm |
|||
Distance ratio |
approx. 75 : 1 (fixed optics 200, 600, 1500) or approx. 100 : 1 (fixed optics 75) |
|||
Measurement accuracy |
0.6 % of measured value in °C or 1 K |
|||
Reproducibility |
0.3 % of measured value in °C or 0.5 K |
|||
NETD |
< 0.15 K |
|||
Response time (t90) |
10 ms (min.), adjustable via RS-485 interface |
|||
Emissivity |
0.200 to 1.000, adjustable via RS-485 interface |
|||
Data storage |
minimum/maximum data storage, adjustable via RS-485 interface |
|||
Output |
0/4 to 20 mA, temperature linear, max. burden: 700 Ω |
|||
Interface |
RS-485 (galvanically isolated), half duplex, max. baud rate 115 kBd, data protocol Modbus RTU |
|||
Aiming |
double laser, 645 nm to 660 nm, class II, < 1 mW |
|||
Switching output/ threshold |
1 opto relay, R Load mind. 48 Ω (galvanically isolated)/adjustable within temperature range |
|||
Software |
PSCSpot for Windows |
|||
Parameters |
emissivity, response time, data storage, sub temperature range, transmissivity, ambient radiation, adjustable via RS-485 interface |
|||
Power supply |
24 V DC ± 25 %, residual ripple 500 mV |
|||
Power consumption |
max. 1.5 W |
|||
Operating temperature |
0 °C to 70 °C (32 °F to 158 °F) |
|||
Storage temperature |
-20 °C to 70 °C (-4 °F to 158 °F) |
|||
Weight |
approx. 600 g (11.5 lbs) |
|||
Housing |
stainless steel round housing with plug connector, length approx. 105 mm, diameter 50 mm |
|||
Protection class |
IP 65 (according to DIN EN 60529 und DIN 40050) |
|||
CE symbol |
according to EU regulations (EN 50 011) |
|||
Scope of delivery |
PSC-T54L, manual, inspection sheet, PSCSpot for Windows ® (without connection cable, please order separately) |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
One-Color Non-Contact Infrared Pyrometers
-
Two-Color Non-Contact Infrared Pyrometers
-
Non-Contact Infrared Pyrometer for Glass Industry Applications
-
Self-Contained Pyrometers for Industrial Applications
-
Compact Two-wire Infrared Thermometer
-
Personal Tracker & Mobile Phone
-
Mobile Time Registration System with GPS receiver and RFID reader
-
STEPPIII Evalkit
-
Antennas for Telematics and AVL systems
-
Solar Power Meter