pH Detector for FIA, HPLC, IEF and Other Low Volume Flow pH Measurements - S450 Series
• pH Range: 0-14 pH Na+ error >12.3 pH)
• Fast response!
• Choice of 200uL or ultra-low volume 50uL flow cells
• Acrylic or PVDF (biocompatible) materials of construction
• Supplied with flangeless 1/4-28 fittings for 1/16” OD for tubing
• Use with Flat-Surface Easy-To-Clean Electrode
• Model available for 100psi use
- Quantity:
- - +
Product Specification
Parts covered by this product data sheet include:
FC45C, FC47C, FC49K, FC51K, 970282, S450CD, 970282,970277
pH Detector Features
• Fast response!
• Choice of 200uL or ultra-low volume 50uL flow cells
• Acrylic or PVDF (biocompatible) materials of construction
• Supplied with flangeless 1/4-28 fittings for 1/16” OD for tubing
• Use with Flat-Surface Easy-To-Clean Electrode
• Model available for 100psi use
The pH Detectors are designed for use with a variety of instrumental techniques such as FIA, HPLC and IEF and are also used to continuously monitor the pH of low volume flows in bench scale chemical systems.
Both the 50 and 200 microliter internal volume flow cells are available in acrylic or PVDF and are supplied with inlet and outlet fittings sized for standard 1/16" OD tubing. The cells' ports have 1/4-28 threads which accept a variety of other tube fittings.
Very low internal volumes are achieved by using a flat surface pH electrode located at the top of the flow cavity. The resulting rectangular cross-section flow path has no protruding parts which could interfere with a clean sweeping flow. The result of this design is the fast system response shown on the performance curves on page 2.
The Flat Surface Electrode, Sensorex Model 450CD, is a combination pH/Reference electrode with double reference junction design. It includes both a pH and reference half cell. The reference electrode is a sealed, gel-filled design and includes a peripheral, semi-porous polyethylene junction.
pH Detector Specifications
pH Range |
0-14 pH Na+ error >12.3 pH) |
Wetted Materials |
Acrylic, PVDF, pH Glass, epoxy, BUNA-N |
Max Temperature |
100 degrees C |
Max Pressure |
60 psig except for 970282 = 100 psig |
Cable Length |
30 inches |
Connectors |
Choice of BNC Others available at additional cost.
|
pH Detector Ordering Information
Flow cells |
|
Part number |
Description |
FC45C |
200uL low volume acrylic flow cell. Includes 2 each 1/16” tube fittings |
FC47C |
50uL low volume acrylic flow cell. Includes 2 each 1/16” tube fittings |
FC49K |
50uL low volume PVDF flow cell. Includes 2 each 1/16” tube fittings |
FC51K |
200uL low volumePVDF flow cell. Includes 2 each 1/16” tube fittings |
970282 |
50uL low volume PVDF flow cell for 100 psig use.
Includes 2 each 1/16” tube fittings |
Electrodes |
|
Part number |
Description |
S450CD |
60 psig rated flat pH electrode with double reference junction, 30 inches of cable and connector choice |
970277 |
100 psig rated flat pH electrode with double reference junction, 30 inches of cable and connector choice. For use with flow cell 970282 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Modular Flat Surface pH & ORP Electrodes
-
Industrial Contacting Conductivity Sensors
-
Toroidal Conductivity Sensor
-
Sanitary Flange Mounted Conductivity/Resistivity Sensor
-
Low Cost Epoxy Body Conductivity Sensors
-
Submersible Flat-Surface, Self-Cleaning pH and ORP Electrodes
-
Side-Stream/By-Pass Flat-Surface, Self-Cleaning pH and ORP Electrodes
-
Ground-Loop Interrupt Flat-Surface Self-Cleaning pH and ORP Electrodes
-
Low Cost Submersion and In-Line pH Electrodes
-
Insertion/Wet-tap Flat-Surface, Self-Cleaning pH and ORP Electrodes