Ozone Monitor and Controller - G09-O3 Series
• Gas Detected: Ozone
• Sensor lifetime: >2 years, removable
• Power Consumption: 2.8W
• Power Supply: 24cVAC/VDC
• Response Time: <50s @T90
• Nonlinear: <1%FS
• Temperature Measuring Range: 5℃~60℃
• Humidity Measuring Range: 0~80%RH
- Quantity:
- - +
Product Specification
G09-O3 Series
Ozone Monitor and Controller with Modbus interface and 1X analog +2X dry contact outputs
• Real time detection and monitoring ambiance ozone level
• Electrochemical ozone sensor inside
• Preset two stage alarm points for ozone measurement
• Buzzer alarm and 3-color backlight LCD indication
• Provide 2x relay dry contact outputs and 1x analog output
• Modbus RS485 communication Interface
• Higher performance with lower price
G09-O3 Series Ozone Monitor and Controller Features
• Design for real time detecting and monitoring ambiance ozone level and temperature
• Electrochemical ozone sensor with high sensitivity
• Particular LCD display with three color backlights (Green/Yellow/Red)
• Maximum ozone measuring range: 0~5000ppb (0~9.81mg/m 3 ) /0~1000ppb mAlso reset the measurement range by end user
• 2xOn/Off dry contact outputs for two stages alarm device, or control a ozone generator or a ventilator
• Buzzer alarm and 3-color backlight LCD indication
• Provide 1X analog output (0,2~10VDC/4~20mA) (can be used as transmitter)
• Modbus RS485 communication interface, 15 KV antistatic protection, individual IP address
• Provide two easy ways for calibration and setup alarm points via an infrared remote controller or via the RS485 interface.
• Temperature measurement and display
• Humidity measurement and display optional
• Multiple application, wall mounting type and desktop type
• Great performance with high quality and low price
G09-O3 Series Ozone Monitor and Controller Application
• Specially used for detecting indoor ambiance quality
• Real time measuring ozone level and analyzing: alarm when ozone level is over proof, control ozone concentrations by controlling related devices in order to reach a certain level in some special places
• Portable type for real time measuring and analyzing
• Anti-epidemic and disease prevention, sanitary inspection, environment protection, health protection, etc. G09-O3 series is the best device used to detect and analyze ozone concentration.
G09-O3 Series Ozone Monitor and Controller Specifications
Gas Detected |
Ozone |
Sensing Element |
Electrochemical gas sensor |
Sensor lifetime |
>2 years, removable |
Temperature Sensor |
NTC |
Humidity Sensor |
HS series capacitive sensor |
Power Supply |
24VAC/VDC (power adaptor selectable) |
Power Consumption |
2.8W |
Response Time |
<50s @T90 |
Signal Update |
1s |
Warm up Time |
<60 seconds |
Ozone Measuring Range |
0~5000ppb (0-5ppm)( 0~9.81mg/m3) 0~1000ppb |
Display Resolution |
1ppb (0.001ppm) (0.01mg/m3) |
Accuracy |
±0.01ppm + 10% reading |
Nonlinear |
<1%FS |
Repeatability |
<0.5% |
Zero Drift |
<1% |
Alarm |
Buzzer and Yellow or Red backlight switch |
Display |
Green-normally, Orange – first stage alarm, Red- second stage alarm. |
Temperature/humidity Measuring Range |
5℃~60℃ (41℉~140℉)/0~80%RH |
Analog Output |
0~10VDC (default) or 4~20mA linear output selectable |
Analog Output Resolution |
16Bit |
Relay dry contact Output |
Two dry-contact outputs Max, switching current 3A (220VAC/30VDC), resistance Load |
Modbus Communication Interface |
Modbus RTU protocol with 19200bps(default) 15KV antistatic protection |
Working Condition/Storage Conditions |
5℃~60℃ (41℉~140℉)/0~ 80% RH |
Net Weight |
190g |
Dimensions |
130mm(H) x 85mm(W) x 36.5mm(D) |
Installation Standard |
65mm x 65mm or 85mm x 85mm or 2"×4" wire box |
Interface Connection (Max) |
9 terminals |
Wiring Standard |
Wire section area <1.5mm2 |
Manufacturing Process |
ISO 9001 Certified |
Housing and IP class |
PC/ABS fireproof plastic material, protection class: IP30 |
Compliance |
EMC Directive 89/336/EEC |
G09-O3 Series Ozone Monitor and Controller Models Guide
G09-O3-ABC1-Y
A-LCD
(2: with LCD, no humidity option, 3: with LCD and with humidity)
B-analog output
(0: no analog output, 1: 0~10VDC output, 2: 4~20mA output)
C-dry contact output
(0: no dry contact output, 1: 1Xdry contact output, 2: 2Xdry contact outputs)
1-Modbus RS485
Y-Ozone range
(B10: 0~1000ppb, B50:0~5000ppb)
Example:
G09-O3-2021-B50 indicates the ozone detector with 2X on/off dry contact outputs and a Modbus RS485 interface, and the ozone range: 0-5000ppb.
G09-O3-3101-B10 indicates the ozone detector with 1X 0~10VDC output and a Modbus RS485 interface, LCD display. Humidity option. ozone range: 0-1000ppb.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-
Gas Alarm System for Detecting Leakage of CO, CombustibLe Gas and Aether