Miniature Size Oxygen Sensor (O2 Sensor) - O2-G1

  • Miniature Size Oxygen Sensor (O2 Sensor)
  • Miniature Size Oxygen Sensor (O2 Sensor)
Mouse over image to zoom

• Output: 65 to 85 μA @ 22℃, 20.9% O2
• Response time t90: < 18 (s) from 20.9% to 0% O2
• Temperature range : -30 to 55 ℃
• Pressure range: 80 to 120 kPa
• Humidity range: 5 to 95 % rh continuous
• Storage period: 6 months @ 3 to 20℃
• Load resistor: 47 to 100 Ω (recommended)
• Weight: <7 g

  • Model Number: O2-G1
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

O2-G1 Oxygen Sensor (O2 Sensor) Description
Alphasense Oxygen sensors use capillary flow control.
Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.

Standard galavanic sensors use lead for greatest reliability but fixed lifetime.

O2-G1 Oxygen Sensor size:
Miniature, proven long-term performance. The sensors are designed for the next generation of portable gas detectors. Part of the Alphasense ‘D‘ family.

O2-G1 Oxygen Sensor Key Features & Benefits:
Small Footprint
Reduced Height
Low Weight
Good Connectivity: Uses industry standard, low cost, Molex sockets for direct board insertion.
Reduced Costs: High quality design with a significant reduction in the cost per measured gas, allied to reduced manufacturing costs are passed on to OEMs


O2-G1 Oxygen Sensor (O2 Sensor) PERFORMANCE

Output
μA @ 22℃, 20.9% O2
65 to 85
Response time
t90 (s) from 20.9% to 0% O2 (47W load resistor)
< 18
Zero current
μA @ 99.999% N 2 , 22℃
< 2.5



O2-G1 Oxygen Sensor (O2 Sensor) LIFETIME
Output drift
% change in output @ 3 months
< 2
Operating life
months until 85% original output in 20.9% O2
> 12



O2-G1 Oxygen Sensor (O2 Sensor) ENVIRONMENTAL


Humidity sensitivity
% O2  change: 0% to 95% rh @ 40℃
< 0.7
CO2  sensitivity
% change in output / % CO2  @ 5% CO2
+ 0.1
Pressure sensitivity
(% change of output)/(% change of pressure) @ 20kPa
< 0.1
Output at -20℃
% output/output at 20℃ in 20.9% O2
87 to 93
Output at +50℃
% output/output at 20℃ in 20.9% O2
103 to 107



O2-G1 Oxygen Sensor (O2 Sensor) KEY SPECIFICATIONS
Temperature range

-30 to 55
Pressure range
kPa
80 to 120
Humidity range
% rh continuous (0 to 99% rh short term)
5 to 95
Storage period
months @ 3 to 20℃ (store in sealed container) 
6
Load resistor
Ω  (recommended)
47 to 100
Weight
g
<7