Miniature & Low Power consumption Type Flammable Gas Sensors - NAP-50A
Supply voltage: DC 2.5±0.25V; AC 2.5±0.25V (r.m.s. 50~60Hz)
Current (at 2.0V): DC 150 - 170mA; A C 150 - 170mA (r.m.s. 50~60Hz)
Operating temp.: -10 ~ +50℃
Operating humidity: 95%RH or less
Output in air: -35 ~ +35mV
- Quantity:
- - +
Product Specification
NAP-50A is a miniature & low power consumption type sensor. NAP-50A is mainly used for gas detectors. Compared to NAP-55A, NAP-50A has a lower alcohol sensitivity to eliminate false alarms caused by alcohol, thus more reliable gas detectors can be produced with NAP-50A. The following are the basic characteristics but it is recommended to refer to the individual user’s manual for further information. See NAP-66A for measuring circuit for sensor evaluation.
* Target gases and detection range
Gases |
Detection range |
||||
Methane |
CH4 |
0.05~ 5% (0.05~ 2%) |
|||
Ethane |
C2H6 |
0.05~ 3.2% (0.05~ 1.5%) |
|||
Iso-butane |
Iso-C4H10 |
0.03~ 1.8% (0.03~ 0.8%) |
|||
Hydrogen |
H2 |
0.05~ 4% (0.05~ 1.5%) |
|||
Hydrocarbons |
CnH2n+2 |
1~100% LEL (1~50%LEL) |
( ) is a detection range in high accuracy
* Ratings
Items |
Ratings |
Supply
Voltage |
DC 2.5 ± 0.25V AC 2.5 ± 0.25V (r.m.s. 50~60Hz) |
Current
(When 2.0V
is applied) |
DC 150 ~ 170mA AC 150 ~ 170mA (r.m.s. 50~60Hz) |
Ambient
Temperature |
In operation -10 ~ +50℃ In storage -10 ~ +50℃ |
Ambient
humidity |
In operation 95%RH or less In storage 99%RH or less (No dew condensation) |
* Gas sensitivity characteristics
Gases & concentration |
Output voltage |
Output in air |
-35 ~ +35mV |
Methane 3000ppm |
10 ~ 16mV |
Iso-butane 1400ppm |
9 ~ 14mV |
Hydrogen 1400ppm |
7 ~ 12mV |
Ethanol 1% |
Less than 10mV |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Combustible Gas Pellistor
-
Smoke Sensor Flammable Gas Sensor
-
Miniature Size Combustible Gas Pellistor
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Higher Temperature Resistivity Flammable Gas Sensors
-
Flammable Gas Sensors Used for Gas Setectors and Leak Testers
-
Higher Temperature Resistivity Flammable Gas Sensors