Humidity with Temperature Sensors - HIH-4602-A/C Series
• Near linear voltage output vs %RH
• Laser-trimmed interchangeability
• Enhanced accuracy, fast response
• Chemically resistant
• Stable, low drift performance
- Quantity:
- - +
Product Specification
Description:
HIH-4602-A/C Series Relative Humidity (RH) sensors combine both relative humidity and temperature sensing in a TO-5 housing with a hydrophobic sintered stainless steel filter.
The laser-trimmed, thermoset polymer capacitive sensing elements have on-chip integrated signal conditioning.
The temperature sensor is thermally connected with the RH sensor making the HIH-4602-A/C often ideal for measuring dew point and other absolute moisture terms.
The HIH-4602-A contains an integral thermistor, while the HIH-4602-C contains an integral precision RTD.
Features:
• Near linear voltage output vs %RH
• Laser-trimmed interchangeability
• Enhanced accuracy, fast response
• Chemically resistant
• Stable, low drift performance
• Built-in static protection
• Often ideal for dew point and absolute moisture measurements
• TO-5 housing
Potential Applications:
• Refrigeration
• Drying
• Meteorology
• Battery-powered systems
• OEM (Original Equipment Manufacturer) assemblies
Performance Specifications (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.):
Parameter |
Minimum |
Typical |
Maximum |
Unit |
Specific Note |
Interchangeability (first order curve) |
— |
— |
— |
— |
— |
0% RH to 59% RH |
-5 |
— |
5 |
% RH |
— |
60% RH to 100% RH |
-8 |
— |
8 |
% RH |
— |
Accuracy (best fit straight line) |
-3.5 |
— |
+3.5 |
% RH |
1 |
Hysterisis |
— |
3 |
— |
% RH |
— |
Repeatability |
— |
±0.5 |
— |
% RH |
— |
Settling time |
— |
— |
70 |
ms |
— |
Response time (1/e in slow moving air) |
— |
50 |
— |
s |
— |
Stability (at 50% RH in one year) |
— |
±1.2 |
— |
% RH |
— |
Voltage supply |
4 |
— |
5.8 |
Vdc |
— |
Current supply |
— |
200 |
500 |
µA |
— |
Output voltage temp. coefficient at 50% RH, 5 V |
— |
-4 |
— |
mV/ºC |
— |
Voltage output (1st order curve fit) |
VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25℃ |
||||
Temperature compensation |
True RH = (sensor RH)/(1.0546-0.00216T), T in℃ |
||||
Operating temperature |
-40[-40] |
See Figure 1. |
85[185] |
℃[ºF] |
— |
Operating humidity |
0 |
See Figure 1. |
100 |
% RH |
2 |
Storage temperature |
-50[-58] |
— |
125[257] |
℃[ºF] |
— |
Storage humidity |
See Figure 2. |
% RH |
2 |
Specific Notes:
1. Device is calibrated at 5 Vdc and 25 ºC.
2. Non-condensing environment.
General Notes:
• Sensor is ratiometric to supply voltage.
• Extended exposure to >90% RH causes a reversible shift of 3% RH.
• Sensor is light sensitive. For best performance, shield sensor from bright light.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Miniature Digital Relative Humidity and Temperature Sensor
-
Probe Style Relative Humidity Sensor Module
-
Capacitive Humidity Sensor
-
Voltage Output Temperature and Humidity Sensor
-
Humidity and Temperature Sensor Module
-
Voltage Output Humidity and Temperature Sensor Module
-
Voltage Output Temperature and Humidity Sensor
-
Temperature Humidity Sensor Module
-
Frequency Output Temperature and Humidity Sensor
-
Capacitive Temperature and Humidity Sensor