High-temperatur Gage Pressure Microelectronic Transducer 0~160MPa, -40℃~+300℃ - MIDA-TG-52
wide pressure range(0~160MPa)
wide temperature range (-40℃~+300℃), low temperature error
high accuracy, high stability
cost-effective
Accuracy: ≤ ±0,25%; ≤ ±0,5%
Supply voltage: 5 - 15 V
- Model Number: MIDA-TG-52
- Quantity:
- - +
Product Specification
High-temperatur Gage Pressure Microelectronic Transducer 0~160MPa, -40℃~+300℃
MIDA-TG-52
Features:
wide pressure range(0~160MPa)
wide temperature range (-40℃~+300℃), low temperature error
high accuracy, high stability
cost-effective
Application:
specially for electric submersible pump and oilfield downhole pressure gauge
industrial process pressure control
aviation and aerospace fields
navigation and shipbuilding industry
petroleum and chemical industry
power plant and nuclear power plants
electrical submersible pump corollary equipment
Specification
Applicationsy | Industrial instrumentation & process control systems |
Measured medium | Fluids and gases compatible with titanium alloys and stainless steels |
Standard ranges, MPa | 0-0,01 … - 0-160 |
Accuracy (comb. L.H.R),no more than, ±% | 0,25; 0,5 |
Zero output, ±mV/1 V of supply voltage | 0,1 (for 0,25%); 0,2 (for 0,5%) |
Output range, mV / V | 5,0+0,2 (3,0+0,2 for 0,01 MPa; 10+0,2 by special request) |
Operating temperature range, ℃ | -40 ... +300 |
Compensated temperature range, ℃ |
+10…+100; +50…+150; +100…+200; +150…+250; +200…+300 |
Additional error within compensated temperature range, no more than, %: of zero output of output range |
1,5 (for 0,25%); 2,5 (for 0,5%) 1,5 (for 0,25%); 2,5 (for 0,5%) |
Supply voltage, V | 5 - 15 |
Input and output resistance, kOhm | Rвх ≥4; Rвых ≤7 |
Overload, no more than | 1,5Рnom (<40 MPa), и 1,25Pnom(>40 MPa) |
Insulation resistance(at temperature of 25 ℃), not less than |
100 MOhm at 100 V |
Overall and mounting dimensions
Temperature at A-zone is up to plus 300 ℃
Temperature at B-zone is up to plus 85℃
Type |
Pnom, MPa |
L, mm (max) |
L1 , mm (max) |
A, mm (max) |
Picture |
MIDA-TG-52
With cable (C)
|
0,04; 0,06 |
231 (M20) 221 (M12) |
69 (M20) 59 (M12) |
137 (M20) 127 (M12) |
2; 1; 2 |
From 0,1 up to 160 (M20) From 0,1 up to 25 (M12) |
233 (M20) 223 (M12) |
72 (M20) 62 (M12) |
140 (M20) 130 (M12) |
3; 1; 3 |
Type |
Pnom, MPa |
L, mm (max) |
L1 , mm (max) |
A, mm (max) |
Picture |
MIDA-TG-52 With plug/socket (P) |
0,04; 0,06 |
240 (M20) 230 (M12) |
69 (M20) 59 (M12) |
137 (M20) 127 (M12) |
2; 4 1; 2; 4 |
From 0,1 up to 160 (M20) From 0,1 up to 25 (M12) |
242 (M20) 232 (M12) |
72 (M20) 62 (M12) |
140 (M20) 130 (M12 |
3; 4 1; 3; 4 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃