• Ranges: 4-14", 5-36"
• Ambient Temperature: 0 - 60ºC or 32 - 140ºF
• Transducer Frequency: 180kHz
• Input Current: 30mA
• Ambient Temperature: 0 - 60ºC or 32 - 140ºF
• Narrow beam sensor
• On/off output with analog capability
• Weight of Controller: 34.2 ounces
• Weight of Transducer: 4.5 ounces

  • Model Number: RPS-300-14-T/RPS-300-36-T
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

RPS-300-T High Frequency Sealed Transducer Unit Features
• Various Sensing Ranges
• Narrow Sensing Beam
• High Frequency
• LED Indicator
• Sealed Transducer
• RPS-500 Compatible
• 3-Way Power Operation
• Isolated Form C Relay Output
• Small Electronic Controller
• Small Remote Transducer
• View Data Sheet

RPS-300-T High Frequency Sealed Transducer Unit Description
The RPS-300-T is a high frequency, sealed transducer unit best suited for environments where chemicals or weld splatter is a problem. The transducer head is constructed of a seamless Teflon body and sensing face. The remote transducer allows for mounting of the sensor head in cramped spaces while the controller is out of the way. The ranging and proximity modes provide the versatility of simple detection, or actual distance measuring. The isolated form C relay furnishes N.O. and N.C. outputs, and with the addition of the RPS-500 card various analog outputs are supplied. The RPS-300-T sensor operates at a frequency of 180kHz for the 14″ and 36″ ranges. This sensor has a narrow sensing beam. Sensing ranges available for the RPS-300-T include 4″ to 14″, 5″ to 36″. Mounting flanges, LED indicator, ranging potentiometer and 6-ft. transducer cable are included. Optional cable lengths are available.


RPS-300-T High Frequency Sealed Transducer Unit Specifications

Operational Range: 
Adjustable 4 - 14”
Adjustable 5 - 36”
Power Input:
  Only 120VAC or 24VDC
  with 500 Analog card.
120VAC
15 - 24VDC
12VDC Regulated
12 - 17VAC
Input Current:
30mA
Input with 500 card:
50mA
Ambient Temperature:
0 - 60ºC or 32 - 140ºF
Controller:
Metal Encloser
Transducer Housing:
Teflon
Output: N.O., N.C.
Isolated Form C Relay
0.5 Amp Maximum at 120VAC
12VDC Logic Signal
Output with 500 card:
0 - 10V, 4 - 20mA Analog Outputs with
Zero, Span, Sample, and Hold controls.
Transducer Frequency:
180kHz
Response Time:
  4 - 14"
  5 - 36"

On = 30ms - 2s; Off = 30ms - 2s
On = 50ms - 2s; Off = 50ms - 2s]
Weight of Controller:
34.2 ounces
Weight of Transducer:
4.5 ounces


PART NUMBER
RANGE
OUTPUT
RPS-300-14-T
RPS-300-36-T
4 - 14"
5 - 36"
Isolated Form C Relay
RPS-300-14-T-500
RPS-300-36-T-500
4 - 14"
5 - 36"
0 - 10V and 4 - 20mA Analog