Heat Flux Sensor - gSKIN-XO

  • Heat Flux Sensor
Mouse over image to zoom

•​ Ultra-high resolution of thermal energies and temperature differences
•​ Robust sensor
•​ Model with connectors compatible with all gSKIN(R) DLOG Data Loggers
• ​Sensor with conductive heat flux calibration cohering to ISO 8301

  • Model Number: gSKIN-XO
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

1.Heat Flux Sensor - gSKIN-XO Descriprion:

    Robust heat flux sensor to perform measures under harsh conditions.

 

2.Heat Flux Sensor - gSKIN-XO Features:

• Ultra-high resolution of thermal energies and temperature differences

• Robust sensor

• Model with connectors compatible with all gSKIN(R) DLOG Data Loggers

• Sensor with conductive heat flux calibration cohering to ISO 8301

 

3.Heat Flux Sensor - gSKIN-XO Applications:

    In-situ building monitoring, U-Value determination, environmental monitoring e.g. soil

 

4.Heat Flux Sensor - gSKIN-XO Technical parameters:

Product

gSKIN XO

Detector Type

Thermoelectric

Surface Material (Sensing Area)

Polyamide

Sensing Dimensions (mm)

30.0 x 30.0 x 3.3

Heat Flux Range Min / Max [kW/m²]

-15/ 15

Noise Equivalent Heat Flux per area [W/m²] / absolute [μW]

0.073 / 65.7 (Experimentally evaluated values under optimal steady state conditions).

Heat Flux Resolution per area [W/m2] with gSKIN® DLOG / absolute [μW]

0.09 / 81.0 (Guaranteed minimum heat flux resolution using the gSKIN® DLOG-4219).

Response Time (0-95%) [s]

n/a

Min. /Avg. Sensitivity (S) [μV/(W/m²)]

10.0/20.0 (Only a reference point).

Max. Compressive Force when clamped [kgf]

>32 (not specified)

Electrical Resistance [Ohm]

<150

Thermal Conductivity [W/(m*K)]

0.4

Absolut Thermal Resistance [K/W]

2.8

Linearity with Power [±%]

1

Operating Temperature Range Min/Max [°C]

-50 / 80

Calibration Accuracy [±%]

3

Calibration Temperature Range Min/Max [°C]

-30 / 70 (Refers to the heat flux measurement).V

Temperature Dependence of S [%/°C]

0.25 (The sensitivity increases/decreases as the temperature goes above/below 22.5°C.

Homogeneity [±%]

1 (Position dependent signal change across sensing area).

Cable Length (c) [cm]

100

 


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service