Hand-Held Combustion Gas Analyzer - IMR 1050X
• Oxygen: 0~21%
• O2 resolution / accuracy: 0.1% / ±0.3%
• Carbon Monoxide (CO): 0~2000 ppm
• Carbon Dioxide (CO2): 0~20%
• CO2 Resolution / accuracy: 0.1% / ±2%
• Efficiency: 0~99.9%
• Efficiency resolution / accuracy: 0.1% / ±3%
• Excess Air: 0~250%
• Excess Air resolution / accuracy: 0.1% / ±3%
- Quantity:
- - +
Product Specification
IMR 1050X Combustion Gas Analyzer Description
The newly redesigned IMR 1050X Combustion System Analyzer eliminates the number one hassle for combustion contractors; the annual replacement and calibration of the O2 sensor. By replacing the electro-chemical O2 sensor with the EOS Technology™ CO2 sensor, the IMR 1050X now takes direct CO2 measurements and calculates the O2 level. This lowers the cost of ownership by doing away with the annual replacements of the O2 sensor and reducing calibration drifting typically found with standard electro-chemical sensors. The EOS Technology sensor has an unmatched industry-leading life expectancy of 10 years!
IMR 1050X Combustion Gas Analyzer Features
• Measures: Differential flue temperature, Carbon Dioxide (CO2), flue & ambient carbon monoxide (CO) & Differential Pressure
• Calculates: oxygen, gross/net efficiency, excess air, & CO air free
• Worklight
• 4 line backlit LCD display
• 179 memory positions
• User customizable parameters view
• Individual report printouts
• Unique DMM style rotary selector
• Protective boot w/integral magnet
• Real time clock
• CO readings to 1 ppm
• Infrared printer port
IMR 1050X Combustion Gas Analyzer Measures, Calculates** or Displays:
• Oxygen (O2)**
• Carbon Monoxide (CO)
• Carbon Dioxide (CO2)
• Combustion efficiency**
• Pressure (draft)
• Date & time
• Temperature (flue, inlet & net**)
• Excess air**
• CO Air Free**
• Battery level
• Fuel type
• Nitric Oxide (IMR 1050X-NO)
IMR 1050X Combustion Gas Analyzer Specifications
Temperature Measurement |
1050X |
1050X‐NO |
Flue Temp Range Inlet Temperature (probe - T2) Inlet Temperature (ambient) Net Temperature (_T)** Resolution Flue (T1, Inlet T2 & _T) Accuracy Inlet Temperature Accuracy |
20~2400°F (-29~1315°C) 20~2400°F (-29~1315°C) 32~112°F (0~50°C) 20~2400°F (-29~1315°C) 0.1°C/F ±(0.3% rdg +3.6°F(2°C)) ±(0.3% rdg +1.8°F(1°C)) |
|
Gas Measurement |
|
|
Oxygen |
0~21%** |
0~21%** |
O2 resolution / accuracy |
0.1% / ±0.3% |
0.1% / ±0.3% |
Carbon Monoxide (CO) |
0~2000 ppm(4000 max 15 min)* |
|
CO resolution / accuracy |
1ppm / ±10ppm < 100ppm ±5% rdg > 100ppm |
|
Carbon Dioxide (CO2) |
0~20% |
0~20% |
CO2 Resolution / accuracy |
0.1% / ±2% |
0.1% / ±2% |
Efficiency** |
0~99.9%** |
0~99.9%** |
Efficiency resolution / accuracy |
0.1% / ±3% |
0.1% / ±3% |
Excess Air** |
0~250% |
0~250% |
Excess Air resolution / accuracy |
0.1% / ±3% |
0.1% / ±3% |
CO / CO2 ratio** |
0~0.999 |
0~0.999 |
CO / CO2 resolution / accuracy |
0.001 / ±5% rdg |
0.001 / ±5% rdg |
Nitric Oxide (NO1) |
- |
0~100 ppm |
NO1 resolution / accuracy |
- |
±5 ppm < 100 ppm |
Pressure (Differential) |
Range |
Accuracy |
|
±0.08" wc (±0.2mBar)
±0.4" wc (±1mBar) ±32"
wc (±80mBar)
|
±0.002" wc (±0.005mBar) ±0.01" wc (±0.03mBar) ±3% rdg |
Pressure Resolution |
0.001" wc < 9.999" wg
0.01" wc < 10.0" wg
0.001 mBar < 24.999 mBar
0.01 mBar > 25 mBar
|
** Calculated value
1050X |
O2, CO2, CO, draft, Condensation Trap, Flue Probe Particle Filter, Hard Case, Batteries,
|
1050X-NO |
O2, CO2, CO, NO, draft, Condensation Trap, Flue Probe, Particle Filter, Hard Case,
|
1050X KIT |
1050X Analyzer, Flue Probe, IR Printer, (2) K-Type Temp Probes, (2) Static Pressure Hoses
|
1050X-NO KIT |
1050X-NO Analyzer Flue Probe, IR Printer, (2) K-Type Temp Probes, (2) Static Pressure Hoses,
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
CO Gas Alarm for CO Detection
-
Combustible, Explosive and Toxic Gas Leak Alarm
-
Natural Gas, CO Leakage Detection with Plug
-
Battery-operated CO Alarm With LCD Display; Comply with EN50291
-
Venus Carbon Monoxide Alarm, Battery-opearated CO Alarm
-
Combustible Gas Alarm with EN50194 Approval
-
Gas Alarm for Combustible Gas and CO Detection
-
Back Plug-in Detector for LPG, Natural Gas and Carbon Monoxide
-
LPG, Natural Gas, CO Gas Alarm
-