Hand-Held Combustion Gas Analyzer - IMR 1050X

  • Hand-Held Combustion Gas Analyzer
  • Hand-Held Combustion Gas Analyzer
Mouse over image to zoom

• Oxygen​: 0~21%
• O2 resolution / accuracy​: 0.1% / ±0.3%​
• Carbon Monoxide (CO)​: 0~2000 ppm
• Carbon Dioxide (CO2)​: 0~20%​
• CO2 Resolution / accuracy​: 0.1% / ±2%​
• Efficiency: 0~99.9%
• Efficiency resolution / accuracy​: ​0.1% / ±3%
• Excess Air: ​0~250%​
• Excess Air resolution / accuracy​: 0.1% / ±3%​

  • Model Number: IMR 1050X
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

IMR 1050X Combustion Gas Analyzer Description
The newly redesigned IMR 1050X Combustion System Analyzer eliminates the number one hassle for combustion contractors; the annual replacement and calibration of the O2 sensor. By replacing the electro-chemical O2 sensor with the EOS Technology™ CO2 sensor, the IMR 1050X now takes direct CO2 measurements and calculates the O2 level. This lowers the cost of ownership by doing away with the annual replacements of the O2 sensor and reducing calibration drifting typically found with standard electro-chemical sensors. The EOS Technology sensor has an unmatched industry-leading life expectancy of 10 years!


IMR 1050X Combustion Gas Analyzer Features
• Measures: Differential flue temperature, Carbon Dioxide (CO2), flue & ambient carbon monoxide (CO) & Differential Pressure
• Calculates: oxygen, gross/net efficiency, excess air, & CO air free
• Worklight
• 4 line backlit LCD display
• 179 memory positions
• User customizable parameters view
• Individual report printouts
• Unique DMM style rotary selector
• Protective boot w/integral magnet
• Real time clock
• CO readings to 1 ppm
• Infrared printer port


IMR 1050X Combustion Gas Analyzer Measures, Calculates** or Displays:
• Oxygen (O2)**
• Carbon Monoxide (CO)
• Carbon Dioxide (CO2)
• Combustion efficiency**
• Pressure (draft)
• Date & time
• Temperature (flue, inlet & net**)
• Excess air**
• CO Air Free**
• Battery level
• Fuel type
• Nitric Oxide (IMR 1050X-NO)


IMR 1050X Combustion Gas Analyzer Specifications

Temperature Measurement
1050X 
1050X‐NO
Flue Temp Range 
Inlet Temperature (probe - T2) Inlet
Temperature (ambient)
Net Temperature (_T)** 
Resolution 
Flue (T1, Inlet T2 & _T) Accuracy 
Inlet Temperature Accuracy
20~2400°F (-29~1315°C)
20~2400°F (-29~1315°C)
32~112°F (0~50°C)
20~2400°F (-29~1315°C)
0.1°C/F
±(0.3% rdg +3.6°F(2°C))
±(0.3% rdg +1.8°F(1°C))
Gas Measurement

Oxygen
0~21%**
0~21%**
O2 resolution / accuracy
0.1% / ±0.3%
0.1% / ±0.3%
Carbon Monoxide (CO)
0~2000 ppm(4000 max 15 min)*
CO resolution / accuracy
1ppm / ±10ppm < 100ppm
±5% rdg > 100ppm
Carbon Dioxide (CO2)
0~20%
0~20%
CO2 Resolution / accuracy
0.1% / ±2%
0.1% / ±2%
Efficiency**
0~99.9%**
0~99.9%**
Efficiency resolution / accuracy
0.1% / ±3%
0.1% / ±3%
Excess Air**
0~250%
0~250%
Excess Air resolution / accuracy
0.1%  / ±3%
0.1%  / ±3%
CO / CO2 ratio**
0~0.999
0~0.999
CO / CO2 resolution / accuracy
0.001 / ±5% rdg
0.001 / ±5% rdg
Nitric Oxide (NO1)
-
0~100 ppm
NO1 resolution / accuracy
- ±5 ppm < 100 ppm
Pressure (Differential)
Range
Accuracy

±0.08" wc (±0.2mBar)
±0.4" wc (±1mBar) ±32"
wc (±80mBar)
±0.002" wc (±0.005mBar)
±0.01" wc (±0.03mBar)
±3% rdg
Pressure Resolution
0.001" wc < 9.999" wg
0.01" wc < 10.0" wg
0.001 mBar < 24.999 mBar
0.01 mBar > 25 mBar
* Measured at STP (standard temperature and pressure)
** Calculated value 


1050X

O2, CO2, CO, draft, Condensation Trap, Flue Probe Particle Filter,  Hard Case,  Batteries, 
Quick Start Guide Owner's Manual

1050X-NO

O2, CO2, CO,  NO, draft, Condensation Trap, Flue Probe, Particle Filter,  Hard Case, 
Batteries, Quick Start Guide Owner's Manua

1050X KIT

1050X Analyzer, Flue Probe, IR Printer, (2) K-Type Temp Probes, (2) Static Pressure Hoses 
(1) True Draft Probe,  Gas Tap and Hose, AC Adapter/Charger, Hard Case, (2) Printer 
paper rolls, (2) Particle filters, Batteries, Quick Start Guide, & Owner's Manual

1050X-NO KIT

1050X-NO Analyzer Flue Probe, IR Printer, (2) K-Type Temp Probes, (2) Static Pressure Hoses, 
(1) True Draft Probe, Gas Tap and Hose, AC Adapter/Charger, Hard Case, (2) Printer 
paper rolls, (2) Particle filters, Batteries, Quick Start Guide, & Owner’s Manual


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service