Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+80℃ - MIDA-TG-51
Wide pressure range 0~160MPa
Operating temperature range -40℃~+80℃
high accuracy, high stability
cost-effective
Accuracy: ≤ ±0,1%; ≤ ±0,2%
Supply voltage: 5 - 15 V
- Model Number: MIDA-TG-51
- Quantity:
- - +
Product Specification
Gage Pressure Microelectronic Transducers 0~160MPa, -40~+80℃
MIDA-TG-51
Features:
Wide pressure range 0~160MPa
Operating temperature range -40℃~+80℃
high accuracy, high stability
cost-effective
Specification
Applicationsy | Industrial instrumentation & process control systems |
Measured medium | Fluids and gases compatible with titanium alloys and stainless steels |
Standard ranges, MPa |
0-0,01 … - 0-160 |
Accuracy (comb. L.H.R),no more than, ±% | 0,1; 0,2 |
Zero output, ±mV/1 V of supply voltage |
0,1 (for 0,1%); 0,2 (for 0,2%) |
Output range, mV / V | 5,0+0,2 (3,0+0,2 for 0,01 MPa; 10+0,2 by special request) |
Operating temperature range, ℃ | -40 ... +80 |
Additional temperature error in operating temperature range (-40…+80℃), no more than, % |
2,0 (for 0,1%); 3,0 (for 0,2%) |
Compensated temperature range, ℃ | --- |
Additional error within compensated temperature range, no more than, %: of zero output of output range |
--- |
Supply voltage, V | 5 - 15 |
Input and output resistance, kOhm | Rвх ≥4; Rвых ≤7 |
Overload, no more than | 1,5Рnom (<40 MPa), и 1,25Pnom(>40 MPa) |
Insulation resistance(at temperature of 25 ℃), not less than |
100 MOhm at 100 V |
Overall and mounting dimensions
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Gage Pressure Transmitters 0~160MPa, -40~80℃
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
High-temperature Gage Pressure Transmitters 0-1.6MPa
-
High-temperature Gage Pressure Transmitters 0-40MPa
-
High-temperature Gage Pressure Transmitters 0-60MPa
-
High-temperature Gage Pressure Transmitters 0-160MPa
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Gage Pressure Microelectronic Transducers 0~160MPa, -40℃~+120℃
-
Absolute Pressure Microelectronic Transducers 0~10MPa, -40℃~+80℃