Flammable Gas Sensors for the Application in Bad Conditions - NAP-50AF
Supply voltage: DC 2.5±0.25V; AC 2.5±0.25V (50-60Hz)
Current (at 2.5V): DC 150 - 170mA; A C 150 - 170mA (50-60Hz)
Operating temp.: -10 ~ +50℃
Operating humidity: less than 95%RH
- Quantity:
- - +
Product Specification
NAP-50AF sensor is newly developed for the application in bad conditions. This sensor is with charcoal filter on NAP-50A sensor. The actual sensitivity is around 10% lower than NAP-50A, but the resistivity to noise gases like silicone compound vapor is quite more excellent than NAP-50A.
* Detected gases and concentration
Gases |
Detection range |
|
Methane |
CH4 |
0.05-5% (0.05-2%) |
Ethane |
C2H6 |
0.05-3.2% (0.05-1.5%) |
Hydrogen |
H2 |
0.05-4% (0.05-1.5%) |
Hydro carbon |
CnH2n+2 |
1-100%LEL (1-50%LEL) |
( ) is a detection range in high
* Ratings
Items |
Ratings |
Supply voltage |
DC 2.5±0.25V AC 2.5±0.25V(50-60Hz) |
Current (at 2.5V) |
DC 150-170mA A C 150-170mA(50-60Hz) |
Ambient temp. |
In operation -10 ~ +50℃ In storage -10 ~ +50℃ |
Ambient humidity |
In operation : less than 95%RH In storage : less than 99%RH (without dew condensation) |
* Gas sensitivity
Gases |
Output signal |
Zero offset in air |
-35 - +35mV |
Methane 4000ppm |
9 - 17mV |
Hydrogen 4000ppm |
8 - 21mV |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Combustible Gas Pellistor
-
Smoke Sensor Flammable Gas Sensor
-
Miniature Size Combustible Gas Pellistor
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Flammable Gas Sensors for Industrial Applications
-
Higher Temperature Resistivity Flammable Gas Sensors
-
Flammable Gas Sensors Used for Gas Setectors and Leak Testers
-
Higher Temperature Resistivity Flammable Gas Sensors